This section relates to the surface preparation, painting and clear finishing of new and existing exterior substrates using Resene Paints Ltd environmental architectural and decorative coating systems.
Modify or extend the above description to suit the project being specified.
Products in this section are ECNZ (Environmental Choice New Zealand) approved unless otherwise noted with NEC (Non-Environmental Choice). Refer Resene Paints Ltd for the full range of Eco Choice approved Resene products including no added VOCs and low VOC products.
This section includes decorative coatings for galvanized/zinc coated steel. For high performance protective coatings, refer to 6745R RESENE PROTECTIVE COATINGS - STEELWORK.
These sections have been written for use with Resene Surface Information & Preparation Data Sheets (SIPDS) and online technical product data sheets. Modify and extend the selected systems (refer to SELECTIONS) as necessary for the substrate and its particular location (e.g. the substrate may be the same for bathroom and bedroom but the finish may differ).
Add project-specific clauses where extensive masking and spraying of coatings is involved. Add clauses when specifying spray or roller-applied high-build products, or when specifying heavy-duty and solid vinyl wall coverings.
For specific technical information call the Resene Technical Helpline 0800 RESENE (0800 737 363) or at www.resene.co.nz
Refer to 6700R RESENE PAINTING GENERAL for general matters related to painting work.
Refer to 6721RE RESENE ENVIRONMENTAL PAINTING INTERIOR for interior paint systems.
Refer to 6711R RESENE PAINTING EXTERIOR for exterior paint systems.
Refer to 6721R RESENE PAINTING INTERIOR for interior paint systems.
The section(s) stated above are often necessary to support this section, consider carefully and ensure they are included in the project specification if required.
Include cross references only to other work sections where they include directly related work.
Refer to the general section 1270 CONSTRUCTION for details of how samples will be reviewed and how instructions to proceed will be given. Provide the following samples for review:
| Sample A | Sample B | Sample C |
Sample description: | ~ | ~ | ~ |
Sample type: | ~ | ~ | ~ |
Number: | ~ | ~ | ~ |
Location: | ~ | ~ | ~ |
Supporting documentation: | ~ | ~ | ~ |
Reviewer: | Contract administrator ~ | Contract administrator ~ | Contract administrator ~ |
Time for review: | 10 working days ~ | 10 working days ~ | 10 working days ~ |
Review criteria: | ~ | ~ | ~ |
The intention of this clause is to allow samples to be obtained that are not otherwise readily available to a reviewer.
Delete rows and columns not required or add "n/a".
Sample description: | Describe the sample, size etc. Prepare samples of the finished work as scheduled, including preparation and colour as specified. |
Sample type: | Portable sample for review Portable control sample Fixed sample for review Fixed control sample
Control samples define requirements for type and quality and are used for comparison purposes throughout the contract.
A "portable" sample is a sample that is easily movable, convenient for carrying. A "fixed" sample is a sample (semi) permanently placed. Expand on these terms as necessary. |
Number: | State number of samples required, e.g. a minimum of three control samples - portable allow a sample to be retained on site with the other samples retained by the contract administrator and contractor. |
Location: | Identify location of fixed samples, e.g. off site, on site, in situ |
Supporting documentation: | Describe any additional documents required to support the review. |
Reviewer: | Modify to suit the project, add additional reviewers if required. |
Time for review: | Alter time if required. Expand to state timing in relation to when and where the sample is provided, e.g. at first site meeting. |
Review criteria: | For example: - Appearance - Texture - Colour Add any critical items. Provide clarity for work that is not dependent on the review to continue. |
Refer to 6700R RESENE PAINTING GENERAL for product clauses.
Modify or extend, including adding clauses to this section where product information relates exclusively to exterior painting.
Refer to 6700R RESENE PAINTING GENERAL for execution clauses.
Modify or extend, including adding clauses to this section where product information relates exclusively to exterior painting.
For further details on selections go to www.resene.co.nz
Substitutions are not permitted to the following, unless stated otherwise.
Select the options to suit the project and delete options not specified.
Stage | Resene SIPDS Spec number/system |
~ | ~ |
The level of inspection will depend on the nature of the project and will range from full for large or complex projects, through to intermittent for straightforward work to occasional for initially establishing the standards of execution. Refer to AS/NZS 2311 Appendix C, Inspection and Testing, for more background.
Paint 2 coats (including any pre-prime) to match exposed face coating.
Cladding type | Extent of back painting |
~ | ~ |
Amend to suit project requirements
Extent options: | To cladding manufacturer's requirements |
| Bottom edge & 150mm up |
| Paint whole back, bottom & concealed edges of cladding |
| Paint cladding under trim before fixing |
| Paint whole back, bottom & concealed edges of trim |
Note;
Some pre-finished cladding may still need back painting.
Paint, stain and clear finishes can have different sorts of requirements.
Hardware for removal: | ~ |
Products in this section are ECNZ (Environmental Choice New Zealand) approved unless otherwise noted with NEC (Non-Environmental Choice). Refer Resene Paints Ltd for the full range of Eco Choice approved Resene products including no added VOCs and low VOC products.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 3/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an Acrylic Weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Flat Mineral effect is required substitute 2nd & 3rd coats with:
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 3/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where High build elastomeric finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
3rd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1C/1 |
1st coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
2nd coat: | Resene Concrete Clear Satin D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Satin D54a, Waterborne Glaze |
This clear system will not render the coated surface weathertight.
Where Flat finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Concrete Clear Flat D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Flat D54a, Waterborne Glaze |
Where Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
All Form Oils and Release Agents must be removed from the surface prior to painting.
Refer to Resene SIPDS 3: 1/1 for surface preparation information.
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an Acrylic Weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Flat Mineral effect is required substitute 2nd & 3rd coats with:
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
All Form Oils and Release Agents must be removed from the surface prior to painting.
Refer to Resene SIPDS 3: 1/1 for surface preparation information.
Where High build elastomeric finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
3rd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1C/1 |
1st coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
2nd coat: | Resene Concrete Clear Satin D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Satin D54a, Waterborne Glaze |
Note: All Form Oils and Release Agents must be removed from the surface prior to painting. Refer to Resene SIPDS 3: 1/1 for surface preparation information.
This clear system will not render the coated surface weathertight.
This section is not suitable for highly polished or honed panels. Contact Resene Architectural & Specifier Services Team.
Where Flat finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Concrete Clear Flat D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Flat D54a, Waterborne Glaze |
Where Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
3rd coat: | Resene Concrete Clear Gloss D54a, Waterborne Glaze |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 2/1 |
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Note: Applied as specified this system achieves>180 microns Dry Film Thickness and meets the requirements of CCANZ CP01 1.1.21 for weathertightness of wall construction type A1 & A3.
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 2/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Note: This system does not meet the requirements of CCANZ CP01 1.1.21 for weathertightness of wall construction type A1 & A3.
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a standard acrylic Semi-Gloss coating is required substitute 2nd, & 3rd coats:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 3/1 |
1st coat: | Resene Limelock D809, Acrylic Cure & Seal |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a standard acrylic Low sheen coating is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a standard acrylic Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Flat Mineral effect is required add 4th coat:
4th coat | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1/3 |
Spot prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Note: If substrate is friable, powdery or efflorescence is present substitute Resene Concrete Primer with Resene Sureseal D42, Solventborne Pigmented Sealer (NEC)
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Flat Mineral effect is required substitute 1st & 2nd coats with:
1st coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 1/3 |
Spot prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Note: If substrate is friable, powdery or efflorescence is present substitute Resene Concrete Primer with Resene Sureseal D42, Solventborne Pigmented Sealer (NEC)
Where High build elastomeric finish is required substitute 1st & 2nd coats with:
1st coat: | Resene X-300E D64, High Build Elastomeric Membrane |
2nd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 2/3 |
Spot prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Note: If substrate is friable, powdery or efflorescence is present substitute Resene Concrete Primer with Resene Sureseal D42, Solventborne Pigmented Sealer (NEC)
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic Weathertight Membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a High Build Elastomeric Membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-300E D64, High Build Elastomeric Membrane |
2nd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
Where a Flat Mineral effect is required substitute 1st & 2nd coats with:
1st coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 3/3 |
Spot prime: | Resene Sureseal D42, Solventborne Pigmented Sealer (NEC) |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic Weathertight Membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a High Build Elastomeric Membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-300E D64, High Build Elastomeric Membrane |
2nd coat: | Resene X-300E D64, High Build Elastomeric Membrane |
Where a Flat Mineral effect is required substitute 1st & 2nd coats with:
1st coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where Anti-Graffiti coatings are required please refer to the Resene Architectural & Specifier Services Team.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 1/1 |
1st coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
3rd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 2/1 |
1st coat: | Resene Wood Primer D40, Solventborne Primer (NEC) |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Timber suppliers typically specify an alkyd solventborne primer to be applied over factory applied alkyd primers. If alkyd solventborne primer is not required by the timber supplier, contact Resene for an alternative specification.
Where a Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
3rd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 1/1 |
1st coat: | Resene Wood Primer D40, Solventborne Primer (NEC) |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Cedar requires an Alkyd solventborne primer to avoid tannin staining issues.
Where a Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
3rd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 7/1 |
1st coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
3rd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
3rd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 8/1 |
1st coat: | Resene Wood Primer D40, Solventborne Primer (NEC) |
2nd coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
3rd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
4th coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
Timber suppliers typically specify an alkyd solventborne primer to be applied over factory applied alkyd primers. If alkyd solventborne primer is not required by the timber supplier, contact Resene for an alternative specification.
Where a Gloss finish is required substitute 3rd & 4th coats with:
3rd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
4th coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 7/1 |
1st coat: | Resene Wood Primer D40, Solvent-borne Primer (NEC) |
2nd coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
3rd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
4th coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
Cedar requires an Alkyd solventborne primer to avoid tannin staining issues.
Where a Gloss finish is required substitute 3rd & 4th coats with:
3rd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
4th coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 4/1 |
1st coat: | Resene Waterborne Woodsman D57a, Waterborne Stain |
2nd coat: | Resene Waterborne Woodsman D57a, Waterborne Stain |
If extra durability is required add a 3rd coat of:
3rd coat: | Resene Waterborne Woodsman D57a, Waterborne Stain |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 16/1 |
1st coat: | Resene Wood Primer D40, Solventborne Primer (NEC) |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Note: Engineered Structural Timber suppliers often provide their own guidelines regarding coating options – typically with Alkyd primers hence Resene Wood primer is included in this section.
Engineered Structural Timber suppliers guidelines should be referred to and take precedence over paint manufacturer’s generic specifications where recommendations differ. Refer to the Resene Architectural & Specifier Services for assistance.
Where a Matt finish is required, substitute 2nd and 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Low Sheen finish is required, substitute 2nd and 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Gloss finish is required, substitute 2nd and 3rd coats with:
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
3rd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 16/1 |
1st coat: | Resene Woodsman Wood Oil Stain D57, Solventborne (NEC) |
2nd coat: | Resene Woodsman Wood Oil Stain D57, Solventborne (NEC) |
Note: Engineered Structural Timber suppliers often provide their own guidelines regarding coating options – typically with oil based stains hence Resene Woodsman Wood Oil is included in this section.
Engineered Structural Timber suppliers guidelines should be referred to and take precedence over paint manufacturer’s generic specifications where recommendations differ. Refer to the Resene Architectural & Specifier Services for assistance.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 6/1 |
1st coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Walk-On Flooring & Paving Paint D322, Waterborne |
3rd coat: | Resene Walk-On Flooring & Paving Paint D322, Waterborne |
Where a standard acrylic Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Non-Skid finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Non-Skid Deck & Path, D313, Acrylic |
3rd coat: | Resene Non-Skid Deck & Path, D313, Acrylic |
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 1/3 |
Spot Prime: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic
|
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Hi-Glo D31, Gloss Acrylic |
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 1/3 |
Spot Prime: | Resene Wood Primer D40, Solvent-borne Primer (NEC) |
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Cedar requires an Alkyd solventborne primer to avoid tannin staining issues.
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Hi-Glo D31, Gloss Acrylic |
2nd coat: | Resene Hi-Glo D31, Gloss Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 7/3 |
Spot Prime: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
1st coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
3rd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
3rd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 7/3 |
Spot Prime: | Resene Wood Primer D40, Solvent-borne Primer (NEC) |
1st coat: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
3rd coat: | Resene Lustacryl D310, Semi-Gloss Waterborne Enamel |
Cedar requires an Alkyd solventborne primer to avoid tannin staining issues.
Where a Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
3rd coat: | Resene Enamacryl D309, Gloss Waterborne Enamel |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 4/3 |
1st coat: | Resene Waterborne Woodsman D57a, Waterborne Stain |
2nd coat: | Resene Waterborne Woodsman D57a, Waterborne Stain |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No2 and Spec Sheet 2: 6/3 |
Spot Prime: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
1st coat: | Resene Walk-On Flooring & Paving Paint D322, Waterborne |
2nd coat: | Resene Walk-On Flooring & Paving Paint D322, Waterborne |
Note: this section assumes the existing coating is acrylic. If it is a polyurethane paving/decking type an adhesion primer of Resene ConcreteSeal 3in1 D409 (NEC) will be required to all existing polyurethane paint coating.
Where a standard acrylic Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Non-Skid finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Non-Skid Deck & Path, D313, Acrylic |
2nd coat: | Resene Non-Skid Deck & Path, D313, Acrylic |
Surface Prep: | Resene SIPDS No4 and Spec Sheet 4: 4/1 |
1st coat: | Resene Galvo-Prime D402, Waterborne Galvanised Steel Primer (NEC) |
2nd coat: | Resene Summit Roof D315s, Satin Acrylic |
3rd coat: | Resene Summit Roof D315s, Satin Acrylic |
Where roof is within 500m of sea apply a second coat of the specified primer prior to topcoats.
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No4 and Spec Sheet 4: 4/3 |
Spot Prime: | Resene Galvo-One D41, Solventborne Galvanised Steel Primer (NEC) |
1st coat: | Resene Summit Roof D315s, Satin Acrylic |
2nd coat: | Resene Summit Roof D315s, Satin Acrylic |
Resene Paints Ltd recommends use of solventborne galvanized steel primer Resene Galvo-One for best long-term performance.
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Flat Mineral effect is required substitute 2nd & 3rd coats with:
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4A/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Flat Mineral effect is required substitute 2nd & 3rd coats with:
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4/3 |
Spot Prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic weathertight membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4A/3 |
Spot Prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 4/3 |
Spot Prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Surface Prep: | Resene SIPDS No5 and Spec Sheet 5: 2/1 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where an acrylic weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Flat Mineral effect is required substitute 2nd & 3rd coats with:
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 3/1 |
1st coat: | Resene Limelock D809, Acrylic Cure & Seal |
2nd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
3rd coat: | Resene AquaShield D601, Acrylic Mineral Effect (NEC) |
Where an acrylic weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where a Matt finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
3rd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where a standard acrylic Low Sheen finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a standard acrylic Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 3: 2/3 |
Spot Prime: | Resene Concrete Primer D405, Acrylic Concrete Primer |
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Note: If substrate is friable/powdery or efflorescence is present substitute Resene Concrete Primer with Resene Sureseal D42, Solventborne Pigmented Sealer (NEC)
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where an acrylic weathertight membrane is required substitute 1st & 2nd coats with:
1st coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where an acrylic Semi-Gloss finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Surface Prep: | Resene SIPDS No3 and Spec Sheet 5: 2/2 |
1st coat: | Resene Concrete Primer D405, Acrylic Concrete Primer |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
3rd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Note: If substrate is friable/powdery or efflorescence is present substitute Resene Concrete Primer with Resene Sureseal D42, Solventborne Pigmented Sealer (NEC)
Where an acrylic weathertight membrane is required substitute 2nd & 3rd coats with:
2nd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
3rd coat: | Resene X-200 D62, Acrylic Weathertight Membrane |
Where an acrylic Semi-Gloss finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
3rd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Surface Prep: | Resene SIPDS No5 and Spec Sheet 5: 1/1 |
Primer: | Not required |
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No5 and Spec Sheet 5: 1/3 |
Spot Prime: | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
1st coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
2nd coat: | Resene Sonyx 101 D30, Semi-Gloss Acrylic |
Where a Matt finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Matt D327, Waterborne Matt |
2nd coat: | Resene Lumbersider Matt D327, Waterborne Matt |
Where Low Sheen finish is required substitute 1st & 2nd coats with:
1st coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
2nd coat: | Resene Lumbersider Low Sheen D34, Waterborne Acrylic |
Consider Resene CoolColour Technology where dark colours are selected.
Surface Prep: | Resene SIPDS No4 and Spec Sheet 4: 2/1 |
1st coat | Resene Galvo-Prime D402, Waterborne Galvanised Primer (NEC) |
2nd coat: | Resene Lustacryl D310, Semi-Gloss waterborne enamel |
3rd coat: | Resene Lustacryl D310, Semi-Gloss waterborne enamel |
Note: This section includes single-pack decorative coatings only.
Where a waterborne Gloss Enamel finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Enamacryl D309, Gloss waterborne enamel |
3rd coat: | Resene Enamacryl D309, Gloss waterborne enamel |
For Resene High Performance 2 pack type systems refer to 6745R RESENE PROTECTIVE COATINGS - STEELWORK
Surface Prep: | Resene SIPDS No4 and Spec Sheet 4: 2/3 |
Spot Prime: | Resene ArmourX GP Metal Primer D411, Solventborne Modified Alkyd (NEC) |
1st coat | Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat |
2nd coat: | Resene Lustacryl D310, Semi-Gloss waterborne enamel |
3rd coat: | Resene Lustacryl D310, Semi-Gloss waterborne enamel |
Note: This section includes single-pack decorative coatings for previously painted steel.
Where a waterborne Gloss Enamel finish is required substitute 2nd & 3rd coats with:
2nd coat: | Resene Enamacryl D309, Gloss waterborne enamel |
3rd coat: | Resene Enamacryl D309, Gloss waterborne enamel |
For Resene High Performance 2 pack type systems refer to 6745R RESENE PROTECTIVE COATINGS - STEELWORK