This section relates to Dulux AcraTex NZ acrylic and polymer-modified cement-based exterior textured plaster systems, applied by hand, pump or hopper gun over:
Modify or extend the above description to suit the project being specified.
This section covers specialist high build coatings, with or without a textured surface, applied by trowel, spray or roller techniques.
While specifically written to suit a range of interior surface finishes, this section could also be adapted to cover similar exterior coatings. However such coating systems are product specific and require careful attention to product manufacturer's preparation and application requirements.
Many exterior coatings are installed as part of a weatherproofing system, including joint sealing/filling. Care is again needed to ensure that both the substrate and coating manufacturer's requirements are strictly adhered to.
Refer to ~ for ~
Include cross references to other sections where these contain related work.
The following abbreviations are used throughout this part of the specification:
PPCS | Proprietary Plaster Cladding Standard |
LBP | Licensed Building Practioner |
AAC | Autoclave Aerated Concrete |
EPS | Expanded Polystyrene |
XPS | Extruded Polystyrene |
ICF | Insulating Concrete Formwork |
MPNZA | Master Painters New Zealand Association |
Refer to the general section 1233 REFERENCED DOCUMENTS. The following documents are specifically referred to in this section:
NZBC B2/AS1 | Durability |
NZBC E2/AS1 | External moisture |
Masonry construction: Materials and workmanship | |
AS 1366.3 | Rigid cellular plastics sheets for thermal insulation - Rigid cellular polystyrene - Moulded (RC/PS - M) |
Guidelines for the provision of facilities and general safety in the construction industry | |
MPNZA | Health and Safety Programme |
Delete from the DOCUMENTS clause any document not cited. List any additional cited documents.
The following are related documents and if referred to in the work section need to be added to the list of DOCUMENTS.
Timber-framed buildings | |
Guide to the painting of buildings | |
Solid plastering, Part 1: Cement plasters for walls, ceilings and soffits | |
BRANZ BU 633 | Removing paint coatings |
BRANZ BU 570 | Ground clearances |
Manufacturer’s and supplier’s documents relating to this part of the work:
List documents relating to this part of the work, i.e. technical product/system specifications, test reports, appraisals, certification, etc.Normally they will be referred to in the text by the abbreviated title.
Use the Dulux AcraTex NZ colour brush outs as a basis of colour where appropriate, order brush outs online at www.dulux.co.nz/specifier/resources/a4-colour-samples.
Manufacturer/supplier contact details
Company: | Dulux AcraTex NZ |
Web: | |
Email: | specifier@dulux.co.nz |
Telephone: | 0800 800 424 |
It is important to ensure that all personnel on site have access to accurate, up to date technical information on the many products, materials and equipment used on a project. In most cases individual products are not used in isolation, but form part of a building process. Also a particular manufacturer's and/or supplier's requirements for handling, storage, preparation, installation, finishing and protection of their product can vary from what might be considered the norm. Access to technical information can help overcome this potential problem.
Provide a material manufacturer/supplier warranty:
10 years | For failure of render materials under normal environmental and use conditions, dependent upon system used |
Refer to the general section 1237 WARRANTIES for additional requirements.
Modify or expand the clause to suit project or manufacturer/supplier requirements, options include:
Provide an applicator warranty:
5 years | For failure of application under normal environmental and use conditions, dependent upon system used |
Refer to the general section 1237 WARRANTIES for additional requirements.
Modify or expand the clause to suit project applicator requirements, options include:
Substitutions are not permitted to any specified Dulux AcraTex NZ system.
Use only PPCS qualified contractors that are experienced, competent, and familiar with the materials and techniques specified. Provide evidence of qualifications on request, in the form of the PPCS National Certificate qualification.
To obtain Dulux AcraTex NZ warranties contractors must be qualified.
Refer to the general section 1270 CONSTRUCTION for details of how samples will be reviewed and how instructions to proceed will be given. Provide the following samples for review:
| Sample A | Sample B | Sample C |
Sample description: | ~ | ~ | ~ |
Sample type: | ~ | ~ | ~ |
Number: | ~ | ~ | ~ |
Location: | ~ | ~ | ~ |
Supporting documentation: | ~ | ~ | ~ |
Reviewer: | Contract administrator ~ | Contract administrator ~ | Contract administrator ~ |
Time for review: | 10 working days ~ | 10 working days ~ | 10 working days ~ |
Review criteria: | ~ | ~ | ~ |
The intention of this clause is to allow samples to be obtained that are not otherwise readily available to a reviewer. Confirmation via a sample of the texture profile is highly recommended.
Delete rows and columns not required or add "n/a"
Sample description: | samples of each specified coating system on a 450mm square of the substrate material being coated. |
Sample type: | Portable sample for review Portable control sample Fixed sample for review Fixed control sample
Control samples define requirements for type and quality and are used for comparison purposes throughout the contract.
A "portable" sample is a sample that is easily movable, convenient for carrying. A "fixed" sample is a sample (semi) permanently placed. Expand on these terms as necessary. |
Number: | State number of samples required, e.g. a minimum of three control samples - portable allow a sample to be retained on site with the other samples retained by the contract administrator and contractor. |
Location: | Identify location of fixed samples, e.g. off site, on site, in situ |
Supporting documentation: | Describe any additional documents required to support the review. |
Reviewer:
| Modify to suit the project, add additional reviewers if required. |
Time for review: | Alter time if required. Expand to state timing in relation to when and where the sample is provided, e.g. at first site meeting. |
Review criteria: | For example: - Appearance - Texture - Colour Add any critical items. Provide clarity for work that is not dependent on the review to continue. |
Use the Dulux AcraTex NZ Architectural Colour Brushouts as a basis of standard where appropriate.
Fax requests to Dulux NZ Customer Services on 0800 805 424 or order Brushouts online at www.dulux.co.nz/specifier/shop.
Use this clause where appearance is the main criteria. Size and form of samples depend on the nature the project.
Contact your Dulux Representative to view texture samples.
Provide Dulux AcraTex NZ Texture Care Guide maintenance instructions before practical completion of the contract for issuing to the building owner.
A copy of the maintenance instructions may be required by the Building Consent Authority with the building consent application,
Provide the PS3 producer statement and workmanship warranty compiled by the LBP contractor who is PPCS qualified in the form as required by the Building Consent Authority.
Refer to the requirements of the Health and Safety at Work Act 2015 updates and WorkSafe: Guidelines for the provision of facilities and general safety in the construction industry.
If the elimination or isolation of potential hazards and risks is not possible then minimise hazards and risks in this work on site by using the proper equipment and techniques as required in the MPNZA Health and Safety Programme. Supply protective clothing and equipment. Inform employees and others on site of the hazards and risks, and put into place procedures for dealing with emergencies. Obtain from Dulux AcraTex NZ the material safety data sheets for each product. Keep sheets on site and comply with the required safety procedures.
Dulux AcraTex NZ recommends the use of the Dulux Envirosolutions wash system for the cleaning of water based paint and plasters from brushes, rollers, plastering or spray equipment. The process separates the solids from the water component for safe disposal. Phone Dulux Customer Services on 0800 800 424 for further information regarding this system.
Refer to Dulux for the material safety data sheets for every applicable product and comply with the safety procedures listed. Keep sheets on the site. Refer to www.dulux.co.nz/specifier or phone Dulux 0800-800-424.
The work covered by this part of the specification has been designed and constructed to NZBC B2/AS1 to achieve a durability of 10 years.
Permit representatives of Dulux AcraTex NZ to inspect the Dulux NZ supplied materials and take samples of their products from site if requested.
The appointed contractor must accept responsibility for the structural and weather-tight performance of the exterior render application.
Confirmation of the protection systems to be applied to fresh plaster coats to be agreed between the main contractor and the licensed applicator before plastering begins.
Normally required curing procedures can be altered when acrylic-modified plasters (bonding agents) have been specified. Such plasters may only need to be protected from direct sun and strong, drying winds for 16 - 24 hours. Consult the manufacturer's requirements in this clause or write another.
Allow to inspect the whole of the work at each stage. Determine a programme for inspections by an approved person including notification when each part and stage of the work is ready for inspection prior to the work commencing.
Dulux AcraTex RenderWall Masonry Render, a coarse grained render ideal for fast application to a true and durable surface. VOC < 1g/L. (Mesh optional as required) Dulux AcraTex Masonry Render is applied not less than 3mm and up to 10mm with a steel trowel.
Dulux AcraTex RenderWall Float Finish Medium, a pre-mixed render formulated to produce a subtle granular texture appearance. VOC < 1g/L.
Used to achieve a grainy texture finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended(site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex AcraPrime 501/10 Green Render Sealer, a water based primer/sealer designed specifically for application over fresh green masonry surfaces. Minimizes unsightly white salts and efflorescence. VOC < 22g/L.
Acrylic texture comprises of either,
A 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by trowel in a single application. VOC < 35g/L.
Used to achieve a tight granular finish.
Two trowel-on acrylic texture options are shown above.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex 952 Spray on 2mm, a 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by hopper gun in a dual application. VOC < 35g/L.
Used to achieve a textured stippled finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex AcraShield Advance, a 100% acrylic mid build, pigmented pure acrylic coating, available in matt and low gloss finishes. Suitable to be applied over cement based plaster finishes as well as acrylic textured surfaces. Dry film per coat 75 microns. VOC < 85g/L.
Dulux AcraTex 968 Elastomeric 201 Matt, an extremely weather resistant high build coating, highly flexible, water based acrylic coating that is a technologically advanced version of an elastomeric membrane with the advantages of a decorative paint. Dry film per coat 125 microns. VOC < 60g/L.
Head, jamb sill and any other required flashings made from uPVC supplied by main contractor for both recessed and faced fixed timber, aluminium and uPVC joinery to NZBC E2/AS1 and masonry construction requirements.
Pre-meshed PVC corner and edge beads.
Used as corner straightening beads.
160 g/m² alkali-resistant fibreglass woven mesh suitable for residential and light commercial projects.
The likelihood of impact damage when used in commercial or industrial situations should be considered at the design stage and appropriate protection, such as bollards or barriers should be provided for vulnerable areas.
Reinforcing not required for use over brick masonry and solid filled masonry unless requested.
When used with Dulux AcraTex RenderWall Masonry Render base coat a full length mesh drop is required, otherwise use 400mm x 400mm strips laid diagonally across all window or door openings for extra impact resistance.
Paintable neutral cure MS Sealant in accordance with Dulux AcraTex NZ manual and set against backer rods where necessary.
Sealant to comply with NZBC E2/AS1 or sealant covered by a valid BRANZ Appraisal for use as a weather sealing sealant for exterior use.
Dulux AcraTex 400/4 Tiltwash, a water based low toxicity cleansing solution to remove bond breakers or release agents from concrete panels prior to the application of a paint/texture system.
Dulux AcraTex 958 AcraSand, A 100% pure acrylic emulsion - contains inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in semi liquid paste consistency the product is designed to be applied by brush and roller. VOC < 35g/litre.
Dulux AcraTex AcraPrime 501/1, a water-based primer/sealer for application over masonry surfaces. VOC < 22g/L.
Acrylic texture comprises of either,
A 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by trowel in a single application. VOC < 35g/L.
Used to achieve a tight granular finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended(site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex 952 Spray on 2mm, a 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by hopper gun in a dual application. VOC < 35g/L.
Used to achieve a textured stippled finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended(site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex AcraShield Advance, a 100% acrylic mid build, pigmented pure acrylic coating, available in matt and low gloss finishes. Suitable to be applied over cement based plaster finishes as well as acrylic textured surfaces. Dry film per coat 75 microns, VOC < 85g/L.
Dulux AcraTex 968 Elastomeric 201 Matt, an extremely weather resistant high build coating, highly flexible, water based acrylic coating that is a technologically advanced version of an elastomeric membrane with the advantages of a decorative paint. Dry film per coat 125 microns, VOC < 60g/L.
Head, jamb sill and any other required flashings made from uPVC supplied by main contractor for both recessed and faced fixed timber, aluminium and uPVC joinery to NZBC E2/AS1 and masonry construction requirements.
Paintable neutral cure MS Sealant in accordance with Dulux AcraTex NZ manual and set against backer rods where necessary.
Dulux AcraTex Tilt Wash 400/4, a water based low toxicity cleansing solution to remove bond breakers from concrete panels prior to the application of a paint/texture system.
Dulux AcraTex AcraPrime 501/10 Green Render Sealer, a water based primer/sealer designed specifically for application over fresh green masonry surfaces. Minimizes unsightly white salts and efflorescence. VOC < 22g/L.
Acrylic texture comprises of either,
A 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by trowel in a single application. VOC < 35g/L.
Used to achieve a tight granular finish.
Two trowel-on acrylic texture options are shown above.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex 952 Spray on 2mm, a 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by hopper gun in a dual application. VOC < 35g/L.
Used to achieve a textured stippled finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rate. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex AcraShield Advance, a 100% acrylic mid build, pigmented pure acrylic coating, available in matt and low gloss finishes. Suitable to be applied over cement based plaster finishes as well as acrylic textured surfaces. Dry film per coat 75 microns, VOC < 85g/L.
Dulux AcraTex 968 Elastomeric 201 Matt, an extremely weather resistant high build coating, highly flexible, water based acrylic coating that is a technologically advanced version of an elastomeric membrane with the advantages of a decorative paint. Dry film per coat 125 microns, VOC < 60g/L.
Head, jamb sill and any other required flashings made from uPVC supplied by main contractor for both recessed and faced fixed timber, aluminium and uPVC joinery to NZBC E2/AS1 and masonry construction requirements.
Paintable neutral cure MS Sealant in accordance with Dulux AcraTex NZ manual and set against backer rods where necessary.
Expanded Polystyrene Sheet, Insulating Concrete Formwork and Extruded Polystyrene Sheet substrates.
EPS sheet to AS 1366.3 class H.
Dulux AcraTex Renderwall P400, a pre-mixed meshing render for use over lightweight substrates, will cure to form a strong base which will accept a textured finish. VOC < 1g/L.
Dulux AcraTex AcraPrime 501/10 Green Render Sealer, a water based primer/sealer designed specifically for application over fresh green masonry surfaces. Minimizes unsightly white salts and efflorescence. VOC < 22g/L.
Dulux AcraTex Renderwall Float Finish Medium, a pre-mixed render formulated to produce a subtle granular texture appearance. VOC < 1g/L.
Used to achieve a grainy texture finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Acrylic texture comprises of either,
A 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by trowel in a single application. VOC < 35g/L.
Used to achieve a tight granular finish.
Two trowel-on acrylic texture options are shown above.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex 952 Spray on 2mm, a 100% pure acrylic emulsion containing inert fillers, graded aggregates, fungicides and colour stable pigments. Supplied in a semi-liquid paste consistency. Product applied by hopper gun in a dual application. VOC < 35g/L.
Used to achieve a textured stippled finish.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Dulux AcraTex AcraShield Advance, a 100% acrylic mid build, pigmented pure acrylic coating, available in matt and low gloss finishes. Suitable to be applied over cement based plaster finishes as well as acrylic textured surfaces. Dry film per coat 75 microns, VOC < 85g/L.
Dulux AcraTex 968 Elastomeric 201 Matt, an extremely weather resistant high build coating, highly flexible, water based acrylic coating that is a technologically advanced version of an elastomeric membrane with the advantages of a decorative paint. Dry film per coat 125 microns, VOC < 60g/L.
Head, jamb sill and any other required flashings made from uPVC supplied by main contractor for both recessed and faced fixed timber, aluminium and uPVC joinery to NZBC E2/AS1 and masonry construction requirements.
Pre-meshed PVC corner and edge beads.
Used as corner straightening beads.
Alkali-resistant fibreglass woven reinforcing mesh with a nominal mesh size of approximately 4mm square and a weight of 160g/m² for domestic and light commercial areas. Where higher impact resistance is required use 360g/m² with nominal size of approximately 5mm x 4mm.
The likelihood of impact damage when used in commercial or industrial situations should be considered at the design stage and appropriate protection, such as bollards or barriers, should be provided for vulnerable areas. Reinforcing not required for use over brick masonry and solid filled masonry unless requested.
Paintable neutral cure MS Sealant in accordance with Dulux AcraTex NZ manual and set against backer rods where necessary.
Sealant to comply with NZBC E2/AS1 or sealant covered by a valid appraisal for use as a weather sealing sealant for exterior use.
Dulux AcraTex AcraPrime 501/1, a water-based primer/sealer for application over masonry surfaces. VOC < 22g/L.
Dulux AcraTex AcraShield Advance, a 100% acrylic mid build, pigmented pure acrylic coating, available in matt and low gloss finishes. Suitable to be applied over cement based plaster finishes as well as acrylic textured surfaces. Dry film per coat 75 microns, VOC < 85g/L.
Dulux AcraTex 968 Elastomeric 201 Matt, an extremely weather resistant high build coating, highly flexible, water based acrylic coating that is a technologically advanced version of an elastomeric membrane with the advantages of a decorative paint. Dry film per coat 125 microns, VOC < 60g/L.
Keep plaster products dry in transit. Take delivery of plaster products dry and undamaged. Reject all damaged materials.
Deliver all materials in original unopened packaging with labels intact. Provide dry storage on site, stack carefully, protect from mechanical damage. Keep bagged render off concrete surfaces. Dispose of any bagged material that is more than 6 months old.
Do not commence work until openings and apertures have been cut, pipes, fixtures, fixing pads and plugs have been fixed and flashings and other preparations are complete. All defects in substrate must be rectified by the trades applicable prior to application of plaster coatings. Ensure that backgrounds and adjoining surfaces are, after the preparation called for in this section, of Dulux AcraTex NZ required standard. All mortar joints to be flush finished and no wider than 15mm, with all nibs and protrusions ground off by the brick / block layer.
Carry out plastering to Dulux AcraTex NZ specification under conditions which will not adversely affect the finished work.
Refer to Manufacturer's Products technical manual.
Before application of plaster, apply masking film and tape to all joinery, pipes, roofs and all areas likely to be marked by the plaster. Use drop cloths and ground covers to keep the working areas clean. Clean off droppings on finished work immediately.
Comply with Dulux AcraTex NZ penetration flashing guidelines. Carry out to the required standard of execution to NZBC E2/AS1 to ensure water does not penetrate.
Head flashings made from powder coated aluminium supplied by main contractor for both recessed and face-fixed timber, aluminium and uPVC joinery. Sub-trade penetrations must be flashed and sealed by that trade.
Comply with the tolerances laid down in NZS 4210 Table 2.2. To have no deviation plus or minus 3mm from a shimmed straight edge 1200mm long.
Before commencing work confirm the layout with the owner, the position of expansion joints and other visual detailing of the finished work.
Before plastering is commenced, eliminate surface contaminants, remove dust, debris, oils, greases, retarders, and paint from already painted surfaces and loose material. Leave the surface dust free and clean. Make good any defects in the background which may adversely affect the adhesion of the plaster coating. Ensure that the background and adjoining surfaces are, after the preparation called for in this section, of the required standard. Do not commence until the pointing is fully cured. Refer to Dulux AcraTex NZ for advice before proceeding.
Defects in substrate by others must be rectified by appropriate trade prior to plaster application commencing.
Fill voids and hollows with a base coat from the Dulux AcraTex range of base and patching compounds dependent on depth to provide a level even plane surface.
Comply with NZBC E2/AS1. All penetrations such as waste pipes, electrical wiring in PVC conduits and metal plumbing piping install with a minimum 5° downward slope, through the plaster system, to be sealed using a double application of MS Sealant after the application of the required base coat plaster and before the plaster finishing coat.
Refer to the WANZ Installation Guide, this covers WANZ recommendations on the preparation of window/door openings, minimum clearances between rough openings and the window/door frame, dressing of the wall wrap/underlay into the prepared opening, application of flexible flashing tape to the sill and top corners of the opening, installation of window/door frames and flashings, sealing of the window/door frame into the opening to create a pressure equalisation cavity, installation of flashings and the maintenance of appropriate clearances between the frame and the surrounding construction.Penetrations through drained cavities to NZBC E2/AS1: External moisture, 9.1.9 Penetrations and 9.1.10 Windows and doors.
A minimum slope of 10° to all horizontal surfaces.
Provide control joints in the plaster to coincide with control joints in the substrate and or junctions between dissimilar substrates in the same plane and or where shown on the drawings and to Dulux AcraTex NZ requirements. Terminate reinforcing mesh each side of control joints. Exposed control joints to be reflected through final coatings from substrate. All control joints to be in place and sealed prior to the commencement of the plastering.
Control Joints to NZS 4251, 2.1.9 Control joints, substrate manufacturer's specifications, and or engineer's requirements.
Install all PVC corner and edge beads necessary and to Dulux AcraTex NZ requirements prior to plaster application commencing.
Refer to SELECTIONS for type and colour.
An LRV 40% minimum is a NZ building code requirement and applies to all monolithic substrates.
Prepare the surface for coating. Ensure the surface is sound and clean by removing any dirt, mould, efflorescence, excess cement and grout. Ensure all protrusions, intrusions and edgings have been satisfactorily prepared.
Apply Dulux AcraTex RenderWall Masonry Render not less than 3mm and up to 10mm with a steel trowel. Apply with firm pressure doubling back with more plaster to achieve a flat uniform finish. Plastering techniques like screeding, floating and scraping can be used to achieve the desired flatness. An alkali reinforced mesh can be laid in the first coat to give further impact resistance.
Apply Dulux Acratex Renderwall Float Finish Medium to produce a granular texture appearance to Dulux AcraTex NZ requirements.
Apply Dulux Acratex AcraPrime 501/10 Green Render Sealer over fresh green masonry surfaces. Apply with roller, brush or airless spray.
Apply Dulux Acratex 951 Super Trowel On 1mm, or Dulux AcraTex 951 Coventry Coarse by steel trowel to the thickness of the aggregate within the emulsion, then float with either a plastic finishing float or polystyrene for the coarser grade aggregate products.
Apply Dulux AcraTex 952 Spray on 2mm using a Hopper Gun with a 4mm tip at 50psi for a 1mm texture and 6 - 8mm tip at 50psi for 2mm texture, on second pass reduce pressure to 30psi.
Apply the specified number of coats of Dulux AcraTex AcraShield Advance with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Apply the specified number of coats of Dulux AcraTex 968 Elastomeric 201 Matt with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Prepare the surface for coating. Ensure the surface is sound and clean by removing any dirt, mould, efflorescence, excess cement and grout. Ensure all protrusions, intrusions and edgings have been satisfactorily prepared.
Apply Dulux AcraTex Tilt Wash 400/4 water based low toxicity cleansing solution to remove bond breakers from concrete panels prior to the application of a paint/texture system. Apply by spray unit.
Apply Dulux AcraTex AcraPrime 501/1 Water Based primer over masonry surfaces. Apply with roller, brush or airless spray.
Apply Dulux AcraTex 958 AcraSand with roller and brush to achieve a fine granular sand finish.
Apply Dulux AcraTex 951 Super Trowel On 1mm, or Dulux AcraTex 951 Coventry Coarse by steel trowel to the thickness of the aggregate within the emulsion, then float with either a plastic finishing float or polystyrene for the coarser grade aggregate products.
Apply Dulux AcraTex 952 Spray on 2mm using a Hopper Gun with a 4mm tip at 50psi for a 1mm texture and 6 - 8mm tip at 50psi for 2mm texture, on second pass reduce pressure to 30psi.
Apply the specified number of coats of Dulux AcraTex AcraShield Advance with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Apply the specified number of coats of Dulux AcraTex 968 Elastomeric 201 Matt with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Prepare the surface for coating. Ensure the surface is sound and clean by removing any dirt, mould, efflorescence, excess cement and grout. Ensure all protrusions, intrusions and edgings have been satisfactorily prepared.
Apply Dulux AcraTex Tilt Wash 400/4 water based low toxicity cleansing solution to remove bond breakers from concrete panels prior to the application of a paint/texture system. Apply by spray unit.
Apply Dulux AcraTex AcraPrime 501/10 Green Render Sealer over fresh green masonry surfaces. Apply with roller, brush or airless spray.
Apply Dulux Acratex 951 Super Trowel On 1mm, or Dulux AcraTex 951 Coventry Coarse by steel trowel to the thickness of the aggregate within the emulsion, and then float with either a plastic finishing float or polystyrene for the coarser grade aggregate products.
Apply Dulux AcraTex 952 Spray on 2mm using a Hopper Gun with a 4mm tip at 50psi for a 1mm texture and 6 - 8mm tip at 50psi for 2mm texture, on second pass reduce pressure to 30psi
Apply the specified number of coats of Dulux AcraTex AcraShield Advance with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Apply the specified number of coats of Dulux AcraTex 968 Elastomeric 201 Matt with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Fix over solid substrate 50mm class H EPS polystyrene sheets. Bond the EPS sheets to the substrate with a notch trowel using Dulux AcraTex RenderWall Detail Render 20 kg bag and fix EPS sheets with polypropylene construction fasteners driven into predrilled holes at 600 mm centres maximum.
Solid substrates such as concrete blocks, brick, precast concrete.
Refer to manufacturer for specific project instructions.
Wait 28 days for concrete to cure before application of plaster system. All surfaces must be rasped to remove the surface skin and any UV light degraded EPS, and to ensure a level plane surface. All window and door joinery to be installed and all penetrations made watertight prior to the commencement of plastering.
Fitting of window and door joinery with air seals, flashings, flexible flashing tape and MS sealant is the responsibility of the window installer
Apply Dulux Acratex RenderWall P400 render coat 3 mm minimum thickness. Embed mesh into the wet plaster. Overlap each successive length by 100 mm minimum. Apply diagonal reinforcement strips at all corners of windows, doors and other exterior openings.
Apply Dulux Acratex RenderWall Float Finish Medium to produce a granular texture appearance to Dulux AcraTex NZ requirements.
Apply Dulux AcraTex AcraPrime 501/10 Green Render Sealer over fresh green masonry surfaces. Apply with roller, brush or airless spray.
Apply Dulux Acratex 951 Super Trowel On 1mm, or Dulux AcraTex 951 Coventry Coarse by steel trowel to the thickness of the aggregate within the emulsion, then float with either a plastic finishing float or polystyrene for the coarser grade aggregate products.
Apply Dulux AcraTex 952 Spray on 2mm using a Hopper Gun with a 4mm tip at 50psi for a 1mm texture and 6 - 8mm tip at 50psi for 2mm texture, on second pass reduce pressure to 30psi.
Apply the specified number of coats of Dulux AcraTex AcraShield Advance with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Apply the specified number of coats of Dulux AcraTex 968 Elastomeric 201 Matt with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Inspect and test the surfaces of existing painted substrates to ensure that they are capable of supporting the new coating. A "cross hatch" adhesion test as an absolute minimum is mandatory, even on a substrate that appears to have a sound firmly adhered paint coating. Carry out testing in many locations and in areas just under window sills, the weather side of the structure and along the lower part of the wall. Remove previous coatings in any areas that fail the adhesion test.
Remove loose or flaky paint (as judged by an adhesion test), dust, dirt, salt deposits, mould /fungi and any other surface contaminants with Dulux Prep Wash. High pressure water blasting is highly recommended as a standard procedure for cleaning the surface; it will also give a good indication as to its integrity.
Repair or fill large cracks and flaws with a suitable patching compound. Smaller cracks (up to 1 mm with Dulux AcraTex 968 Elastomeric 201 or 650 µm with Dulux AcraTex AcraShield Advance) do not need to be filled as these will be bridged by the topcoat.
Where the previous coating is removed back to the bare substrate or repairs have been carried out, spot priming will be required. Dulux AcraTex AcraPrime 501/1 water based primer is recommended, unless the surface is particularly powdery and friable, in which case Dulux AcraTex AcraPrime 501/2 solvent based is recommended.
Apply Dulux AcraTex AcraPrime 501/1water-based primer/sealer.
Apply the specified number of coats of Dulux AcraTex AcraShield Advance with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
Apply the specified number of coats of Dulux AcraTex 968 Elastomeric 201 Matt with roller, brush or airless spray to the recommended spread rate as per DuSpec specification shown in SELECTIONS.
All freshly applied materials to be protected from inclement weather for a minimum of 24 hours after application.
Remove covers and masking carefully and at the correct time, to avoid damage to or lifting of the coating edge. Clean adjoining surfaces, glass and fittings of contamination.
Remove debris, unused materials and elements from the site relating to the plaster system application. Replace damaged, cracked or marked elements. Leave the whole of this work to the required standard.
For further details on selections go to www.dulux.co.nz/specifier or www.duspec.co.nz.
Substitutions are not permitted to the following, unless stated otherwise.
If substitutions are permitted modify the statement above, ensure the NO SUBSTITUTIONS clause from GENERAL is treated the same.
Select the options to suit the project and delete options not specified.
SELECTIONS is for providing details of the actual selections to be included in the contract works including model numbers, colours and other information necessary to ensure that the correct materials are supplied and installed.
Customise the attached schedules or substitute a schedule prepared using the DuSpec system.
When specifying texture coatings Dulux recommend that consideration should be given to the type and profile of the texture and preparation of the substrate to achieve the specified texture as this will impact on the applied m² rates. Confirmation via a sample of the texture profile is highly recommended (site sample applied by the contractor is preferred) prior to final pricing sign-off by the contractor administrator.
Contact a Dulux representative for a texture sample.
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
4th coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09611.
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
4th coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
4th coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09612.
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
4th coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 952 Spray on 2mm |
4th coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09613.
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 952 Spray on 2mm |
4th coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex RenderWall Float Finish Medium |
3rd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
4th coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
5th coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09614.
Substrate: | Masonry, AAC, brick and/or block |
System: | |
1st coat: | DULUX AcraTex RenderWall Masonry Render |
2nd coat: | DULUX AcraTex RenderWall Float Finish Medium |
3rd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
4th coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
5th coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex 958 AcraSand Roll On |
2nd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09615.
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex 958 AcraSand Roll On |
2nd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex 958 AcraSand Roll On |
2nd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09616.
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex 958 AcraSand Roll On |
2nd coat: | DULUX AcraTex 951 Super Trowel on 1mm |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 952 Spray on 2mm |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish in some colours.
Refer to system specification NZ_SA09617.
Substrate: | Tilt-up and precast concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 952 Spray on 2mm |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA09619.
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA09620.
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 952 Spray on 2mm |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA09621.
Substrate: | Off the form concrete |
System: | |
Preparation: | DULUX AcraTex 400/4 Tiltwash |
1st coat: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 952 Spray on 2mm |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
For cementitious surtaces that have less than 28 days curing Dulux recommend the use of AcraTex 501 Green Render Sealer rather than AcraPrime 501/1.
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
4th coat | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA08678.
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Coventry Coarse Trowel On |
4th coat | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
4th coat | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours
Refer to system specification NZ_SA08681.
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 951 Super Trowel On 1mm |
4th coat | DULUX AcraTex 968 Elastomeric 201 High Build Mat |
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 952 Spray on 2mm |
4th coat | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours
Refer to system specification NZ_SA08685.
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
3rd coat: | DULUX AcraTex 952 Spray on 2mm |
4th coat | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex RenderWall Float Finish Medium |
3rd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
4th coat | DULUX AcraTex AcraShield Advance Mid Build Matt |
5th coat | DULUX AcraTex AcraShield Advance Mid Build Matt |
AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA08689.
Substrate: | Polystyrene |
System: | |
1st coat: | DULUX AcraTex RenderWall P400 |
2nd coat: | DULUX AcraTex RenderWall Float Finish Medium |
3rd coat: | DULUX AcraTex AcraPrime 501/10 Green Render Sealer |
4th coat | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
5th coat | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
System: | |
1st coat: | DULUX Prep Wash |
Spot prime: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
3rd coat: | DULUX AcraTex AcraShield Advance Mid Build Matt |
Dulux AcraTex AcraShield Advance topcoat also available in a Low Gloss finish.in some colours.
Refer to system specification NZ_SA08757.
System: | |
1st coat: | Dulux Prep Wash |
Spot prime: | DULUX AcraTex AcraPrime 501/1 Water Based |
2nd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |
3rd coat: | DULUX AcraTex 968 Elastomeric 201 High Build Matt |