If you have pre-customised this work section using the "questions and answers" provided as part of the downloading process, it may be necessary to amend some clauses to suit the final project-specific version.
The section must still be checked and customised to suit the project being specified, by removing any other irrelevant details and adding project-specific details and selections.
This section relates to the manufacture, supply and installation of AceDoor Systems 2013 Limited commercial and industrial doors.
It includes;
Modify or extend the above description to suit the project being specified.
Refer to the general section 1232 INTERPRETATION & DEFINITIONS for abbreviations and definitions used throughout the specification.
The following abbreviations apply specifically to this section:
LCM | Low Cycle Motor |
HDM | Heavy duty motor |
MDM | Medium duty motor |
LDM | Light duty motor |
CSFM | California State Fire Marshal |
cUL | Underwriters Laboratory (Canada) |
UL | Underwriters Laboratory (USA) |
The following definitions apply specifically to this section:
AceDoors | AceDoor Systems 2013 Limited |
Delete abbreviations or definitions that are not used.
Refer to ~ for ~
Refer to the appropriate electrical section for power supply to motorise doors and grilles.
Include cross references to other sections where these contain related work. These may include, a glazing section for glazing not forming part of the proprietary door, a painting section for painting not forming part of the proprietary door or an electrical section for power supply to opening system.
Generally, hardware is supplied and installed as part of the door package. However, it will be necessary to confirm preferred selection from the range of options offered by the manufacturer.
Refer to the general section 1233 REFERENCED DOCUMENTS. The following documents are specifically referred to in this section:
NZBC C/AS1, C/AS2 | Protection from fire |
Fire tests on building materials and structures. Methods for determination of the fire resistance of non-bearing elements of construction | |
AS/NZS 1170.2: 2011 | Structural design actions - Wind actions |
AS 1530.4 | Methods of fire tests on building materials, components and structures - Fire-resistance tests of elements of building construction |
Timber-framed buildings | |
Glazing in buildings - Human impact safety requirements | |
Fire-resistant door-sets | |
BS 7346.4 | Components for smoke and heat control systems. Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. |
AS/NZS 4024 | Safety of machinery |
Garage doors and other large access doors |
Note; for health and safety reasons this section uses the most up to date version of NZS 4223.3:2016. This new version complies with the NZBC by matching or exceeding Acceptable Solution requirements, although it is an Alternative Solution because the NZBC Acceptable Solutions cites the old version NZS 4223.3:1999.
Note: AS/NZS 1170.2:2011 is cited in NZBC B1/VM1 Structure at the time of writing. The new version AS/NZS 1170.2:2021 is not yet cited. Amend the section by removing the year reference if using the 2021 version and amend the section accordingly.
Delete from the DOCUMENTS clause any document not cited. List any additional cited documents.
The following are related documents and if referred to in the work section need to be added to the list of DOCUMENTS.
BRANZ BU 369 | Fitting tolerances |
Refer to the general section 1237 WARRANTIES & 1237WA WARRANTY AGREEMENT (if required) for additional requirements.
Refer to general section 1235 SHOP DRAWINGS for the requirements for submission, review and the provision of shop drawings.
Ensure correct Wind Zone information is supplied in 1220 PROJECT.
Refer to general section 1250 TEMPORARY WORKS & SERVICES clause SPECIAL PROTECTION.
Manufacturer's and supplier's documents relating to work in this section are:
AceDoors Technical Data Sheets
AceDoors Installation Manual
List documents relating to this part of the work, i.e. technical product/system specification, appraisals, etc. Normally they will be referred to in the text by the abbreviated title.
Manufacturer/supplier contact details
Company: | AceDoor Systems 2013 Limited |
Web: | |
Email: | sales@acedoors.co.nz |
Telephone: | 0800 366 773 |
| 09 273 4970 |
It is important to ensure that all personnel on site have access to accurate, up-to-date technical information on the many products, materials and equipment used on a project. In most cases individual products are not used in isolation, but form part of a building process. Also a particular manufacturer's and/or supplier's requirements for handling, storage, preparation, installation, finishing and protection of their product can vary from what might be considered the norm. Access to technical information can help overcome this potential problem.
Provide a material manufacturer/supplier warranty:
Refer to AceDoors for specific warranty terms & conditions for materials & fabrication
Refer to the general section 1237 WARRANTIES for additional requirements.
Modify or expand the clause to suit project or manufacturer/supplier requirements, options include:
Provide an installer warranty:
1 year: For Installation
Refer to the general section 1237 WARRANTIES for additional requirements.
Modify or expand the clause to suit project or installer requirements, options include:
Installers to be experienced, competent door technicians familiar with the installation of the AceDoors equipment and approved by the manufacturer. If requested, provide evidence of qualification / experience prior to commencing work.
This clause includes generic text which should be expanded only if there are specific qualification requirements.
Where a product or material supplier is named in SELECTIONS, the product/material must be provided by the named supplier. Where more than one named supplier, any one of the named suppliers will be acceptable.
This clause is used to nominate a supplier or suppliers to supply materials. It is not intended for nominating subcontractors which must be done in the specific conditions of contract applying to the work. Check with BCA for acceptability of multiple selection options.
Substitutions are not permitted to any of the AceDoors specified systems, components or associated products listed in this section.
Refer to the general section 1235 SHOP DRAWINGS for the requirements for submission, review and the provision of shop drawings.
Provide shop drawings to show the general arrangement including, but not limited to:
If requested provide the following additional information:
~
Submit shop drawings for review to ~,
The general section 1235 SHOP DRAWINGS (1234 DOCUMENTATION if not available) describes the process of submission and review of shop drawings. Use this clause to describe the specific requirements of what the required shop drawings are to include.
Provide the following general operation and maintenance information as electronic PDF format documents:
Use this clause to list requirements of information that is required but which does not warrant a separate specialist operation and maintenance manual. Amend the clause if hard copy documents are required.
Provide this information prior to Practical Completion.
Provide the following compliance documentation: -
List the Producer Statements - Construction (PS3) and Construction Review (PS4) required from installers and engineering consultants that are required as a condition of carrying out this work.
Accept responsibility for the structural and limited weathertight performance of the completed door installation.
Use this standard generic clause and add specific requirements where necessary. There are no standards relating to weathertightness for industrial and commercial doors. Do not expect them to be fully weathertight or watertight.
The next two mutually exclusive clauses, are setting a standard of performance for design by the contractor. Specifiers should therefore consider adding some means of confirming (say by testing or certification) that the performance criteria will be or have been met. Delete the clause which does not apply.
Ensure the relevant Wind Zone information is supplied in 1220 PROJECT section.
Design the installation to the wind zone parameters of NZS 3604, 'Timber framed buildings', table 5.4.
Specify relevant wind speed or pressure.
Delete the clause if using DESIGN PARAMETERS - SPECIFIC DESIGN.
Design the installation to the wind pressure parameters of AS/NZS 1170.2 'Structural design actions - Wind actions' and to the manufacturer's installation instructions.
Specify relevant wind speed or pressure.
Use this standard generic clause and add specific requirements where necessary.
Obtain information from the project structural engineer.
Delete the clause if using DESIGN PARAMETERS - NON SPECIFIC DESIGN.
Group Number to NZBC C/AS2, Table 4.3 Fire - Acceptable Solutions. Refer to SELECTIONS.
NOTE: For most internal applications a surface fire performance Group Number will be required to NZBC C/AS2, table 4.3. If the Group number is established from NZBC C/AS2 Appendix C, Table C1.2, add to clause.
Delete clause if not required. A Group number may not be required in situations such as, the surface area is less than 5m² (NZBC C/AS2, 4.17.6.a), or the design is to NZBC C/AS1 risk group SH (houses, etc.).
To NZBC C/AS1, 5.4 Exterior surface finishes or NZBC C/AS2, 5.8 External cladding systems or NZBC C/VM2.
Add test results here if necessary.
Delete if not required.
Check with the door manufacturer that the proposed construction of the wall is compatible with and matches the requirements of the selected door assembly before proceeding with construction of the door and wall.
Use this standard generic clause and add specific requirements where necessary.
Where the proposed door or installation does not comply with the standard or where other conditions apply, obtain an assessment from a registered testing laboratory or a Registered Fire Engineer to satisfy the requirements of NZBC C/AS1or NZBC C/AS2 'Protection from fire'.
Note: Conditions which may apply prior to manufacture include allowance for sufficient assessment time, addition of a PC Sum for testing procedure, etc, - matters which should be addressed in the contract documents.
In-situ touch-up of coating is only permitted after receiving written direction from the Contract Administrator. Replace damaged components or material not able to be restored to as-new condition.
Use this standard generic clause and add specific requirements where necessary.
The Q&A process should remove any doors which are not relevant to the project. If necessary, delete door types not required.
AceDoors DuraShutter™ Steel Roller Shutter, constructed from individually roll formed 0.75mm thick replaceable interlocking galvanised steel slats. Operation by motorisation or manual hand chain, custom made to fit size of opening and structure of building up to 8m wide x 7m high. Galvanized or Duralloy powder coat finishes and vented slats available. Meets or exceeds wind load requirements of AS/NZS 4505 'Garage doors and other large access doors' and meets the updated requirements of AS/NZS 1170.2, amendment 4.
Refer to SELECTIONS for sizes, motor types, guide type (wind loading) and finishing details
Suitable for factories, warehouses, industrial buildings, carparks, shop fronts, etc.,.requiring secure and reliable closing capabilities. Replaceable slats are more economic following, for example, vehicle impact.
AceDoors SpiraDoor™ aluminium insulated slat door constructed from interlocking slats of 200mm x 47mm sections consisting of two materials; a hollow extruded aluminium section filled with an insulating core of expanded polyurethane foam. Motorised operation. Refer to SELECTIONS.
Suitable where security and high speed operation is necessary, instead of roller shutter/fabric high speed door combinations.
AceDoors DuraDoor™Panel Doors fabricated from powdercoated sheet aluminium injected with PUR polyurethane core. Supplied in 42mm standard thickness, complete with all hardware. Maximum leaf size is 2300mm high x 1150mm wide. Refer to SELECTIONS for type and finishing details.
Suitable for factories, warehouses, industrial buildings, public toilets, schools, hotels and heavy duty applications.
AceDoors Personnel Door fabricated from 0.6mm Colorsteel injected with PUR polyurethane core to produce a 40mm standard thickness, complete with all hardware. Maximum leaf size is 2300mm high x 1100mm wide. Refer to SELECTIONS for type and finishing details.
Suitable for sheds, barns and domestic garages.
AceDoors AlumaView™ Sectional Overhead Door, glazed to NZS 4223.3 'Glazing in buildings - Human impact safety requirements' extruded aluminium sections operated by spring balance, hand-chain or motorised. Supplied to fit the size of opening; vertical stacking, high lift or standard lift. Silver anodised or powder coat finish. Refer to SELECTIONS for maximum sizes, operation types, headroom configuration, panel layout and finishing details.
Suitable for fire stations, ambulance bays, bus depots, service stations and schools where a high level of visibility is required..
AceDoors Insulated Traffic Doors fabricated from rigid PVC extrusion with thermo-plastic facings and PUR polyurethane insulated core. Max leaf size 2750mm x 2400mm wide, 44mm thick, complete with all hardware. Available with vision panels 740mm x 235mm wide or 540mm x 540mm wide. Refer to SELECTIONS for type and finishing details.
Suitable for factories, supermarkets, warehouses, industrial buildings, schools, hotels and heavy duty applications.
AceDoors Process Door Sets fabricated from a 50mm thick EPS/PIR fire rated panel with Colorsteel facing. Fitted with PVC double gasket seals and heavy duty S/S butt hinges in a one-piece aluminium profile frame. Available with vision panels 500mm x 500mm or 800mm x 200mm in 4mm or 6mm glass to NZS 4223.3 'Glazing in buildings - Human impact safety requirements'. Refer to SELECTIONS for type and finishing details.
Suitable for hygeine and processing areas. General purpose door for industrial buildings.
AceDoors CoolClad™ Doors for industrial cool stores, chiller rooms and freezers. Fabricated from powder-coated Colorsteel with PUR injected polyurethane insulation core, overall thickness is 91mm. Rise and fall hinges allow three-way adjustment of food-grade silicone rubber gaskets fitted to the perimeter. Max opening size, single hinged - 2300mm x 1100mm wide. Max opening size, double hinged - 2000mm x 2000mm. Refer to SELECTIONS for type and finishing details.
Suitable for industrial cool stores, chiller rooms and freezers.
AceDoors Insulated Sliding Door Sets for industrial cool stores, chiller rooms and freezers. Fabricated from 50mm, 75mm, 100mm and 150mm EPS/PIR panel with Colorsteel facing. Available in process, medium and low temperature specifications. Food-grade silicone rubber gaskets fitted to the perimeter. Mill finish aluminium alloy extrusion frame and track with nylon wheels. Refer to SELECTIONS for type and finishing details.
Suitable for industrial cool stores, chiller rooms and freezers.
AceDoors PVC Strip Curtains custom made of 100mm, 200mm or 300mm wide strip in ambient or freezer temperature grade PVC to suit each application, from chiller and coolroom openings to large openings with forklift traffic. Refer to SELECTIONS for type and details.
Suitable for factories, warehouses, industrial buildings, food processing areas, supermarkets, retail food outlets.
AceDoors PVC Swing Doors for heavy duty trolley and pallet traffic, single or double-leaf, double-action doors available with stay-open or self-closing options. Manufactured in two models, Hygiene Swingdoor™ for general use or Clear-Vu Swingdoor™ for heavy-duty situations. Refer to SELECTIONS for type and details.
Suitable for factories, warehouses, industrial buildings, food processing areas, supermarkets, retail food outlets.
Kent Automatic Fire Curtains consist of a fire resistant fibreglass fabric wound round a roller encased in a head box, typically installed above the ceiling, remaining out of sight until activated. When activated, the curtain rolls down to close off the opening to minimise fire spread, meeting the requirements of NZBC C/AS1 or NZBC C/AS2 'Protection from fire'. Refer to SELECTIONS for type and details.
Suitable for all building types where fire control is required.
Kent Automatic Smoke Curtains consist of a fire resistant fibreglass fabric wound round a roller encased in a head box, typically installed above the ceiling, remaining out of sight until activated. When activated, the curtain descends to channel smoke to extraction points within the building, meeting the requirements of NZBC C/AS1 or NZBC C/AS2 'Protection from fire'. Refer to SELECTIONS for type and details.
Suitable for all building types where smoke control is required.
Purpose built electric motor assembly, complete with alternative method of operation required in the event of power failure. Depending on application - Low Cycle Motors (LCM) for smaller commercial units; internal barrel where there is a risk of tampering with the motor, or 3-phase motors for heavier duty industrial doors.
Refer to SELECTIONS.
Delete clause if spring balance or handchain operated. Modify clause to suit model selected.
Note; AS/NZS 4024 requires machine guarding below 2.5m above floor level. Specify if this is to be provided by AceDoors or by other means, e.g. concealment
Opening, closing, security logic control and safety devices, etc., required for the operation of the door. Refer to SELECTIONS.
Modify clause to suit project.. With exterior doors, check that interior opening devices can not be illicitly activated from outside.
Refer to the general section 1270 CONSTRUCTION section for requirements relating to delivery, storage and handling of products. Take delivery of materials and goods, store on site and protect from damage. Move/handle goods in accordance with manufacturer's requirements. Reject and replace goods that are damaged or will not provide the required finish.
The general section 1270 CONSTRUCTION describes how deliveries are to be managed and the goods stored.
Refer to the general section 1250 TEMPORARY WORKS & SERVICES for protection requirements. Refer to 1270 CONSTRUCTION for requirements relating to defective or damaged work, removal of protection and cleaning.
Use this standard generic clause and if appropriate add special requirements.
Check that the trimmed and lined openings are formed and constructed to suit the required units. Do not proceed until openings are properly formed to the required standard and AceDoors requirements.
Install door, track and operating equipment complete with all specified and necessary accessories and hardware to the manufacturer's requirements.
Use this standard generic clause and add specific requirements where necessary.
Refer to the general section 1270 CONSTRUCTION for general requirements.
Amend this clause to describe specific standards and tolerances to be achieved in carrying out this part of the work. Although such tolerances are typically included in standards (NZS, AS/NZS, etc.) in certain circumstances it is worth restating these in this clause.
Install AceDoors DuraShutter™ Steel Roller Shutter in accordance with manufacturer's installation instructions. Ensure shutter guides are square and plumb. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary. Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Install AceDoors SpiraDoor™ High Speed Spiral Door in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary. Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Install AceDoors DuraDoor™ panel door in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors Personnel Door panel door in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors AlumaView™ Sectional Overhead Door in accordance with AceDoors installation instructions. Ensure door guides are square and plumb. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary. Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Install AceDoors Thermal Insulated Traffic Door in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors Process Doors and Frames in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors CoolClad™ Thermal Insulated Door in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors Thermal Insulated Sliding Door in accordance with manufacturer's installation instructions. Concealed floor track (if applicable) to be installed by others. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors PVC Strip Curtain in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors PVC Swing Doors in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary.
Install AceDoors - Kent Fire Curtain in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary. Co-ordinate with ELECTRICAL section for connection to alarm system and control panels.
Install AceDoors - Kent Smoke Curtain in accordance with manufacturer's installation instructions. Refer to Completion & Commissioning.
Use this standard generic clause and add specific requirements where necessary. Co-ordinate with ELECTRICAL section for connection to alarm system and control panels.
Repair damaged or marked elements. Replace damaged or marked elements where repair is not possible or will not be acceptable. Adjust operation of equipment and moving parts not working correctly. Leave work to the standard required for following procedures.
Use this standard generic clause and add specific requirements where necessary.
Main Contractor to provide the following temporary protection of the finished work:
~
Amend this clause if protection is required from, weather, water, dust, damage, etc. Refer to the general section 1270 CONSTRUCTION for removal as part of final clean.
If special protection is required or protection is to be supplied by others, make reference in this clause to the general section 1250 TEMPORARY WORKS & SERVICES clause SPECIAL PROTECTION.
Refer to the general section 1270 CONSTRUCTION for completion requirements and if required commissioning requirements. Door installer to carry out a manual verification of the operation of the door.
Electrician to provide isolator, connect power supply, set limits and commission the door operation.
Use this standard generic clause and if appropriate add special requirements.
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
For further details on selections go to www.acedoors.co.nz
Substitutions are not permitted to the following AceDoors equipment, components or accessories.
SELECTIONS is for providing details of the actual selections to be included in the contract works including motor options, colours and other information necessary to ensure that the correct materials are supplied and installed. Refer to details of requirements for wall structures, clearances and fixing points.
Group Number | Panel/Finish | Location |
|
|
|
~ | ~ | ~ |
Fire Test Report: add details if necessary
If the Group number is established from NZBC C/AS2 Appendix C, Table C1.2, add to clause.
Delete clause if not required. A Group number may not be required in situations such as, the surface area is less than 5m² (NZBC C/AS2, 4.17.6.a), or the design is to NZBC C/AS1 risk group SH (houses, etc.).
Select the options to suit the project and delete options not specified.
Location: | ~ |
Brand: | AceDoors DuraShutter™ Steel Roller Shutter |
Size: | Refer to drawings |
Operation type: | ~ |
Guide type: | ~ |
Personnel door: | ~ |
Slats: | ~ |
Finish: | ~ |
Motor cover: | ~ |
Options:
Operation type: | GB, LCM, internal barrel motor options, manual handchain or spring balance |
Guide type: | Standard, Windlock |
Slats: | 0.8mm thick galvanized nominal 100mm pitch, plain or vented |
Finish: | Galvanized or powdercoated |
Motor cover: | AS/NZS 4024 requires machine guarding below 2.5m. Specify if this is to be provided by AceDoors or by other means, e.g. concealment |
Refer to AceDoors Roller Shutter Windloading Chart for selection criteria. Windlock guides offered as standard for doors over 5m width.
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand: | AceDoors SpiraDoor™ High Speed Roller Shutter |
Size: | Refer to drawings |
Operation type: | ~ |
Guide type: | Standard |
Slats: | 200mm x 47mm aluminium PUR filled slats |
Finish: | Powdercoated |
Motor cover: |
|
Options:
Operation type: | GB, LCM, internal barrel motor options |
Motor cover: | AS/NZS 4024 requires machine guarding below 2.5m. Specify if this is to be provided by AceDoors or by other means, e.g. concealment |
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand: | AceDoors DuraDoor™ Panel Door |
Type: | ~ |
Wall type: | ~ |
Size: | Refer to drawings |
Frame profile: | ~ |
Meeting stiles (pairs): | ~ |
Edge: | ~ |
Glazing beads: | ~ |
Glazing: | ~ |
Fixings: | ~ |
Finish: | ~ |
Options:
Type: | Single or double leaf hinged |
Wall type: | Timber, steel or concrete masonry |
Frame profile: | Standard profile or as detailed |
Meeting stiles (pairs): | Square edge or overlap meeting stile angle |
Glazing beads: | Interior fitted or exterior fitted |
Glazing: | Georgian Wired glass in adhesive rubber seal, as selected to comply with NZS 4223.3. |
Fixings: | Stainless steel or galvanized |
Finish: | Mill finish or powdercoated. |
Location: | ~ |
Brand: | AceDoors Personnel Panel Door |
Type: | ~ |
Wall type: | ~ |
Size: | Refer to drawings |
Frame profile: | ~ |
Meeting stiles (pairs): | ~ |
Edge: | ~ |
Glazing beads: | ~ |
Glazing: | ~ |
Fixings: | ~ |
Finish: | ~ |
Options:
Type: | Single or double leaf hinged |
Wall type: | Timber, steel or concrete masonry |
Frame profile: | Standard profile or as detailed |
Meeting stiles (pairs): | Square edge or overlap meeting stile angle |
Glazing beads: | Interior fitted or exterior fitted |
Glazing: | Georgian Wired glass in adhesive rubber seal, as selected to comply with NZS 4223.3. |
Fixings: | Stainless steel or galvanized |
Finish: | Colorsteel, mill finish or powdercoated |
Location: | ~ |
Brand: | AceDoors AlumaView™ Sectional Overhead Door |
Type: | Panoramic glazed |
Size: | Refer to drawings |
Configuration: | ~ |
Operation type: | ~ |
Override: | ~ |
Door cladding: | ~ |
Options:
Configuration: | Standard, Low head room, Follow the roof, Full vertical, Lift clear |
Operation type: | Manual push-up, chain hoist, motorised (single or three phase) |
Over ride: | Push up, hand-chain or crank (refer to AceDoors for details) |
Door cladding: | Panoramic: aluminium door sections (anodised or powdercoated) 4mm or 6.38mm laminated glass infill and bottom leaf aluminium infill panel, or as specified, to comply with NZS 4223.3 |
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand: | AceDoors Insulated Traffic Panel Door |
Type: | ~ |
Wall type: | ~ |
Size: | Refer to drawings |
Frame profile: | ~ |
Meeting stiles (pairs): | ~ |
Edge: | ~ |
Glazing beads: | ~ |
Glazing: | ~ |
Fixings: | ~ |
Finish: | ~ |
Options:
Type: | Single or double leaf hinged |
Wall type: | Timber, steel or concrete masonry |
Frame profile: | Standard profile or as detailed |
Meeting stiles (pairs): | Square edge or overlap meeting stile angle |
Glazing beads: | Interior fitted or exterior fitted |
Glazing: | Georgian Wired glass in adhesive rubber seal, as selected to comply with NZS 4223.3. |
Fixings: | Stainless steel or galvanized |
Finish: | Black, dark grey or beige (other colours can be supplied on request) |
Location: | ~ |
Brand: | AceDoors Process Panel Door |
Type: | ~ |
Wall type: | ~ |
Size: | Refer to drawings |
Frame profile: | ~ |
Meeting stiles (pairs): | ~ |
Edge: | ~ |
Glazing beads: | ~ |
Glazing: | ~ |
Fixings: | ~ |
Finish: | ~ |
Options:
Type: | Single or double leaf hinged |
Wall type: | Timber, steel or concrete masonry |
Frame profile: | Standard profile or as detailed |
Meeting stiles (pairs): | Square edge or overlap meeting stile angle |
Glazing beads: | Interior fitted or exterior fitted |
Glazing: | Georgian Wired glass in adhesive rubber seal, as selected to comply with NZS 4223.3. |
Fixings: | Stainless steel or galvanized |
Finish: | Steel or Colorsteel |
Location: | ~ |
Brand: | AceDoors CoolClad™ Panel Doors and Frames |
Type: | ~ |
Wall type: | ~ |
Size: | Refer to drawings |
Frame profile: | ~ |
Meeting stiles (pairs): | ~ |
Edge: | ~ |
Glazing beads: | ~ |
Glazing: | ~ |
Fixings: | ~ |
Finish: | ~ |
Options:
Type: | Single or double leaf hinged |
Wall type: | Timber, steel or concrete masonry |
Frame profile: | Standard profile or as detailed |
Meeting stiles (pairs): | Square edge or overlap meeting stile angle |
Glazing beads: | Interior fitted or exterior fitted |
Glazing: | Georgian Wired glass in adhesive rubber seal, as selected to comply with NZS 4223.3. |
Fixings: | Stainless steel or galvanized |
Finish: | Colorsteel |
Location: | ~ |
Brand: | AceDoors Insulated Sliding Door |
Size: | Refer to drawings |
Track: | ~ |
Operation: | ~ |
Cladding: | ~ |
Options:
Track: | Top track with floor guide, floor track with top guide |
Operation: | Manual or rack and pinion motorised (single phase) |
Cladding | Proprietary aluminium or steel cladding profiles as selected |
Location: | ~ |
Brand: | AceDoors PVC Strip Curtain |
Type: | ~ |
Strip width: | ~ |
Colour: | ~ |
Size: | Refer to drawings |
Fixings: | ~ |
Track: | ~ |
Options:
Type: | ambient or freezer grade, flat or double ribbed |
Strip width: | 100mm 200mm or 300mm |
Fixings: | Head or face fixed |
Track: | Sliding track system available |
Location: | ~ |
Brand: | AceDoors PVC Swing Door |
Type: | ~ |
Size: | Refer to drawings |
Fixings: | ~ |
Operation: | ~ |
Options:
Type: | Hygiene™ Swingdoor or Clear-Vu™ Swingdoor |
Location: | ~ |
Brand: | AceDoors - Kent Automatic Fire Curtain |
Model No. | ~ |
Fire resistance: | ~ |
Radiation protection: | Up to 60 minutes <15kW/m² |
Standard: | ~ |
Size: | Refer to drawings |
Operation: | ~ |
Tested to BS EN 1634-1 Fire Resistance and BS EN 1634-3 Smoke Control
Options:
Model No. | Standard |
AFC01S-455 | UL |
AFC01M-455 | UL |
AFC03S-690 | UL |
AFC03M-690 | UL |
AFC01S-455S | UL |
AFC01M-455S | UL |
AFC03S-690S | UL |
AFC03M-690S | UL |
AFC02S | BS EN |
AFC02M | BS EN |
AFC03S | BS EN |
AFC03M | BS EN |
Fire resistance: | 60 minutes for VG 455 |
| 120 minutes for VWG 520 |
| 180 minutes for VWG 690 |
Operation: | fusible link, smoke/heat detector or fire alarm activated |
Co-ordinate with ELECTRICAL section for connection to alarm system and control panels.
Location: | ~ |
Brand: | AceDoors - Kent Automatic Smoke Curtain |
Model No. | ~ |
Fire resistance: | Up to 120 minutes |
Standard: | ~ |
Size: | Refer to drawings |
Operation: | ~ |
Tested to BS EN 12101-1Options:
Options:
Model No. | Standard |
ASC01S-455 | UL |
ASC01M-455 | UL |
ASC03S-690 | UL |
ASC03M-690 | UL |
ASC01S-455S | UL |
ASC01M-455S | UL |
ASC03S-690S | UL |
ASC03M-690S | UL |
ASC01 D | BS EN |
ASCO1 DH | BS EN |
Fire integrity: | 120 minutes at 600ºC (BS EN 12101-1 Annex D) |
| 60 minutes at 1000ºC (BS EN 12101-1 Annex D) |
| 60 minutes at 1000ºC (UL 10D) |
Operation: | local smoke detection or central fire alarm activated |
Co-ordinate with ELECTRICAL section for connection to alarm system and control panels.
Consider how the door is to operate;
Opening - manual, push button sensor, card swipe/reader, key pad, remote control
Closing - manual, push button sensor, remote control, timer
Security - manual locks, electronic locks, alarm connection
Safety - drop down protection, fail safe, obstruction sensors, fire alarm connection, battery back up
Refer to www.acedoors.co.nz for more details and options.
Location: | ~ |
Controls: | ~ |
Accessories: | ~ |
Options:
Controls: | Standard 'inching Up/Down or 'Maintained' Up/Stop/ 'inching' Down |
Accessories: | Key-switch master keyable flush mounted, or Key-switch master keyable surface mounted in stainless steel enclosure, or Key-switch surface mounted in plastic enclosure |
Location: | ~ |
Controls: | Remote control complete with safety beam and One Touch Key-chain Transmitters |
Transmitters: | ~ |
Option:
Transmitters: | Specify quantity of transmitters required |
Location: | ~ |
Controls: | Complete with safety beam. Door closes automatically on an adjustable timer. |
Interfacing: | ~ |
Transmitters: | ~ |
Options:
Interfacing: | External inputs - swipe cards, proximity readers, keypads, fire alarm, induction loops (supplied by Security Contractor) |
Transmitters: | Specify quantity of transmitters, if remote controls required |
Compatible with security monitoring and building management systems.
The following clauses are typical for roller doors. Select from AceDoors size chart to suit application. Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Supply: | Single phase |
Override: | Automatic hand chain |
Used for small low usage doors.
Key-switches, remotes and safety beams are available, but not logic controls.
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Supply: | Single phase |
Override: | Hand crank |
Used where, due to accessibilty, there is a risk of public interference with the motor, eg, externally mounted doors or where a minimised barrel profile is requred.
Motor is concealed within the barrel.
Key-switches, remotes and safety beams available but not logic controls.
For security, coupling and crank handle can be removed until required.
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand/type: | Three phase 0.37kW |
Override: | Manually engaged hand-chain |
Used for factory and warehouse doors. Full range of control options available.
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand/type: | Three phase 0.75kW |
Override: | Manually engaged hand-chain |
Used for mid-range size doors
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Brand/type: | Three phase 1.50kW |
Override: | Manually engaged hand-chain |
Used for larger doors such as carparks, high cycle applications, vented areas.
Note; AS/NZS 4024 requires machine guarding below 2.5m above floor level. Specify if this is to be provided by AceDoors or by other means, e.g. concealment
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.
Location: | ~ |
Type: | ~ |
Options:
Type: |
|
Manual: | Hand-chain,crank, refer to appropriate SELECTION clauses above |
Electrical: | Either battery back up unit (single phase) or on-site UPS |
Co-ordinate with ELECTRICAL section for power connection to motors and control panels.