6721RE
RESENE ENVIRONMENTAL PAINTING INTERIOR
1
GENERAL

If you have pre-customised this work section using the "questions and answers" provided as part of the downloading process, it may be necessary to amend some clauses to suit the final project-specific version.

 

The section must still be checked and customised to suit the project being specified, by removing any other irrelevant details and adding project-specific details and selections.

 

This section relates to the surface preparation, painting and clear finishing of new and existing interior substrates using Resene environmental architectural and decorative coating systems.

Modify or extend the above description to suit the project being specified.

 

This 6721RE RESENE ENVIRONMENTAL PAINTING INTERIOR section is intended to be combined as appropriate with the sections listed below and they collectively comprise painting work:

 

These sections have been written for use with Resene Surface Information & Preparation Data Sheets (SIPDS) and online technical product data sheets. Modify and extend the selected systems (refer to SELECTIONS) as necessary for the substrate and its particular location (e.g. the substrate may be the same for bathroom and bedroom but the finish may differ).

 

 Every endeavour has been made to ensure all products in this section are waterborne/Low or Ultra Low VOC & ECNZ approved (Environmental Choice New Zealand) however where system performance would be significantly comprised (NEC) Non-Environmental Choice NZ products have been suggested or specified.

 

Add project-specific clauses where extensive masking and spraying of coatings is involved; especially where solventborne products are specified. Add clauses when specifying spray or roller-applied high-build products, or when specifying heavy-duty and solid vinyl wallcoverings.

 

For specific technical information call the Resene Technical Helpline 0800 RESENE (0800 737 363) or at www.resene.co.nz

Related work
1.1
RELATED WORK

Refer to 6700R RESENE PAINTING GENERAL for general matters related to painting work.

Refer to 6711RE RESENE ENVIRONMENTAL PAINTING EXTERIOR for exterior paint systems.

Modify or delete, include cross references to other sections where these contain related work.

Other related sections in Masterspec Standard could be 6745R RESENE PROTECTIVE COATINGS - STEELWORK for protective coatings.

Requirements
1.2
SAMPLES

Refer to the general section 1270 CONSTRUCTION for details of how samples will be reviewed and how instructions to proceed will be given.  Provide the following samples for review:

 

Sample A

Sample B

Sample C

Sample description:

~

~

~

Sample type:

~

~

~

Number:

~

~

~

Location:

~

~

~

Supporting documentation:

~

~

~

Reviewer:

Contract administrator

~

Contract administrator

~

Contract administrator

~

Time for review:

10 working days ~

10 working days ~

10 working days ~

Review criteria:

~

~

 

The intention of this clause is to allow samples to be obtained that are not otherwise readily available to a reviewer.

                                                                                                                                                                                                                 Delete rows and columns not required or add "n/a".

Sample description:

Describe the sample, size etc.

Prepare samples of the finished work as scheduled, including preparation and colour as specified.

Sample type:

Portable sample for review

Portable control sample

Fixed sample for review

Fixed control sample

 

Control samples define requirements for type and quality and are used for comparison purposes throughout the contract.

 

A "portable" sample is a sample that is easily movable, convenient for carrying. A "fixed" sample is a sample (semi) permanently placed. Expand on these terms as necessary.

Number:

State number of samples required, e.g. a minimum of three control samples - portable allow a sample to be retained on site with the other samples retained by the contract administrator and contractor.

Location:

Identify location of fixed samples, e.g. off site, on site, in situ

Supporting documentation:

Describe any additional documents required to support the review.

Reviewer:

Modify to suit the project, add additional reviewers if required

Time for review:

Alter time if required. Expand to state timing in relation to when and where the sample is provided, e.g. at first site meeting.

Review criteria:

For example:

- Appearance

- Texture

- Colour

Add any critical items. Provide clarity for work that is not dependent on the review to continue.

2
PRODUCTS
Materials
2.1
PAINT TYPES GENERALLY/ THINNERS AND ADDITIVES

Refer to 6700R RESENE PAINTING GENERAL for product clauses.

Modify or extend, including adding clauses to this section where product information relates exclusively to interior painting.

3
EXECUTION
Conditions
3.1
EXECUTION

Refer to 6700R RESENE PAINTING GENERAL for execution clauses.

Modify or extend, including adding clauses to this section where product information relates exclusively to interior painting.

4
SELECTIONS

For further details on selections go to www.resene.co.nz

Substitutions are not permitted to the following, unless stated otherwise.

If substitutions are permitted modify the statement above, ensure the NO SUBSTITUTIONS clause from GENERAL is treated the same.

 

Select the options to suit the project and delete options not specified.

4.1
INSPECTION OF WORK

Stage

Resene SIPDS number/system

~

~

The level of inspection will depend on the nature of the project and will range from full for large or complex projects, through to intermittent for straightforward work to occasional for initially establishing the standards of execution.

4.2
BACK PAINTING SCHDULE

Paint 2 coats (including any pre-prime) usually to match exposed face coating.  If there is no coating use water resistant clear finish sealer.

Lining type        

Extent of back painting        

~

~

Amend to suit project requirements

Extent options:

To lining manufacturer's requirements

 

Bottom edge & 150mm up

 

Paint whole back, bottom & concealed edges of lining

 

Paint lining under trim before fixing

 

Paint whole back, bottom & concealed edges of trim

Note;

In most cases only a requirement of wet/damp area linings.

Some pre-finished lining may still need backpainting in wet areas.

Paint, stain and clear finishes can have different sorts of requirements.

Some tiled substrates are recommended to have the whole back painted/sealed.

4.3
HARDWARE

Hardware for removal:

~

Resene interior paint systems

INTERIOR PAINT SYSTEMS: Supply the listed Resene systems for the following substrates.

Note: Select the appropriate first coat by deleting those not applicable.

 

ENVIRONMENTAL CHOICE NZ

All products in this section are ECNZ (Environmental Choice New Zealand) approved unless otherwise noted with NEC (Non-Environmental Choice)

For a current list of Resene Environmental Choice NZ approved paints see www.resene.co.nz/comn/envissue/paintlst.htm

 

All products in this section are ECNZ (Environmental Choice New Zealand) approved unless otherwise noted with NEC (Non-Environmental Choice)

 

VOLATILE ORGANIC COMPOUNDS (VOCs)

For a current list of VOCs for Resene products see www.resene.co.nz/archspec/datashts/vocsummary.pdf.

 

GREEN STAR

For information on how to earn Green Star NZ points with paint see www.resene.co.nz/greenstarnz.htm.

Environmental interior plasterboard - new
4.4
NEW INTERIOR PLASTERBOARD WALLS; DRY AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S. Test Report FH4967

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene Zylone Sheen D302, Waterborne Low Sheen

3rd coat:

Resene Zylone Sheen D302, Waterborne Low Sheen

Notes:

1: If top coats are changed it may alter the Fire Rating Test Report details.

2: Refer to AS/NZS 2589 for guidelines on level of finish. Areas of  "Critical Light" require a level 5 finish

 

For improved level of surface finish substitute 1st coat with:

1st coat:

      Resene Broadwall Surface Prep & Seal D807, Waterborne

For high traffic areas where durable coating is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Where Flat finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

4.5
NEW INTERIOR PLASTERBOARD WALLS; DRY AREAS (ULTRA LOW VOC)

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S. Test Report FH4967

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene Zylone Sheen Zero D302, Waterborne Low Sheen

3rd coat:

Resene Zylone Sheen Zero D302, Waterborne Low Sheen

Notes:

1: If top coats are changed it may alter the Fire Rating Test Report details.

2: Refer to AS/NZS 2589 for guidelines on level of finish. Areas of  "Critical Light" require a level 5 finish

3: All products in this section are 5g/L VOC or less.

4.6
NEW INTERIOR PLASTERBOARD WALLS; WET AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/1

Fire rating:

Group 1-S. Test Report 7-593235-CO

1st coat

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Flat finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

3rd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

4.7
NEW INTERIOR PLASTERBOARD WALLS; CLINICAL DRY AREAS (ULTRA LOW VOC) HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S, Test Report FH4925

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene ClinicalCote Satin D318, Waterborne

3rd coat:

Resene ClinicalCote Satin D318, Waterborne

Note 1: If top coats are changed it may alter the Fire Rating Test Report details

2: All products in this section are 5g/L VOC or less.

 

Where Low Sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

3rd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

4.8
NEW INTERIOR PLASTERBOARD WALLS; CLINICAL WET AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/1

Fire rating:

Group 1-S. Test Report 7-593235-CO

1st coat

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

3rd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

4.9
NEW INTERIOR PLASTERBOARD CEILINGS; DRY AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S, Test Report FH4967

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene Ceiling Paint D305, Waterborne Flat

3rd coat:

Resene Ceiling Paint D305, Waterborne Flat

Notes:
1: If top coats are changed it may alter the Fire Rating Test Report details.
2: Refer to AS/NZS 2589 for guidelines on level of finish. Areas of  "Critical Light" require a level 5 finish

 

For an improved level of surface finish substitute 1st coat with:

1st coat:

Resene Broadwall Surface Prep & Seal D807, Waterborne

Where durable easily cleaned coating is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

4.10
NEW INTERIOR PLASTERBOARD CEILINGS; DRY AREAS (ULTRA LOW VOC)

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S, Test Report FH4967

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene Ceiling Paint D305, Waterborne Flat

3rd coat:

Resene Ceiling Paint D305, Waterborne Flat

Notes:
1: If top coats are changed it may alter the Fire Rating Test Report details.
2: Refer to AS/NZS 2589 for guidelines on level of finish. Areas of  "Critical Light" require a level 5 finish

3: All products in this section are 5g/L VOC or less.

4.11
NEW INTERIOR PLASTERBOARD CEILINGS; WET AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/1

Fire rating:

Group 1-S

1st coat

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

2nd coat:

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

Where Low Sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

3rd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

4.12
NEW INTERIOR PLASTERBOARD CEILINGS; CLINICAL DRY AREAS (ULTRA LOW VOC) HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S, Test Report FH4925

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

3rd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

All products in this section are 5g/L VOC or less.

4.13
NEW INTERIOR PLASTERBOARD CEILINGS; CLINICAL WET AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/1

Fire rating:

Group 1-S

1st coat

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

3rd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

Environmental Plasterboard – Existing
4.14
EXISTING INTERIOR PLASTERBOARD WALLS; DRY AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/1

Fire rating:

Group 1-S, Test Report FH4925

1st coat

Resene Broadwall D403, Waterborne Wallboard Sealer

2nd coat:

Resene Zylone Sheen D302, Waterborne Low Sheen

3rd coat:

Resene Zylone Sheen D302, Waterborne Low Sheen

For high traffic areas where durable coating is required substitute 2nd & 3rd coats with

1st coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

4.15
EXISTING INTERIOR PLASTERBOARD WALLS; DRY AREAS (ULTRA LOW VOC)

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/3

Spot Prime:

Resene Broadwall D403, Waterborne Wallboard Sealer

1st coat

Resene Zylone Sheen Zero D302, Waterborne Low Sheen

2nd coat:

Resene Zylone Sheen Zero D302, Waterborne Low Sheen

All products in this section are 5g/L VOC or less.

4.16
EXISTING INTERIOR PLASTERBOARD WALLS; WET AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/3

Spot Prime:

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

1st coat

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 1st & 2nd coats with:

1st coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

4.17
EXISTING INTERIOR PLASTERBOARD WALLS; CLINICAL DRY AREAS (ULTRA LOW VOC) HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/3

Spot Prime:

Resene Broadwall D403, Waterborne Wallboard Sealer

1st coat

Resene ClinicalCote Satin D318, Waterborne

2nd coat:

Resene ClinicalCote Satin D318, Waterborne

 All products in this section are 5g/L VOC or less.

 

Where Low Sheen finish is required substitute 1st & 2nd coats with:

1st coat:

Resene ClinicalCote Low Sheen D318, Waterborne

2nd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

4.18
EXISTING INTERIOR PLASTERBOARD WALLS; CLINICAL WET AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/3

Spot Prime:

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

1st coat

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 1st & 2nd coats with:

1st coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

2nd coat:

Resene Lustacryl Kitchen & Bathroom D310K, Waterborne Enamel

4.19
EXISTING INTERIOR PLASTERBOARD CEILINGS; DRY AREAS (ULTRA LOW VOC)

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/3

Spot Prime:

Resene Broadwall D403, Waterborne Wallboard Sealer

1st coat

Resene Ceiling Paint D305, Waterborne Flat

2nd coat:

Resene Ceiling Paint D305, Waterborne Flat

All products in this section are 5g/L VOC or less.

4.20
EXISTING INTERIOR PLASTERBOARD CEILINGS; WET AREAS

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/3

Spot Prime:

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

1st coat

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat Kitchen & Bathroom D314K, Waterborne Enamel

Where Semi-Gloss finish is required substitute 1st & 2nd coats with:

1st coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

4.21
EXISTING INTERIOR PLASTERBOARD CEILINGS; CLINICAL DRY AREAS (ULTRA LOW VOC) HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1: 1/3

Spot Prime:

Resene Broadwall D403, Waterborne Wallboard Sealer

1st coat:

Resene ClinicalCote Low Sheen D318, Waterborne

2nd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

All products in this section are 5g/L VOC or less.

4.22
EXISTING INTERIOR PLASTERBOARD CEILINGS; CLINICAL WET AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No1 and Spec Sheet 1A: 1/3

Spot Prime:

Resene Waterborne Sureseal D42a, Waterborne Pigmented Sealer

1st coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen Kitchen & Bathroom D311K, Waterborne Enamel

Environmental interior timber - new
4.23
NEW INTERIOR TIMBER DOORS, JOINERY, SKIRTING

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 9/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Enamacryl D309, Waterborne Enamel

3rd coat:

Resene Enamacryl D309, Waterborne Enamel

Where a Low sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

4.24
NEW INTERIOR TIMBER DOORS, JOINERY; CEDAR

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 9/1

1st coat

Resene Enamel Undercoat D44, Solvent-borne Undercoat (NEC)

2nd coat:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

4th coat:

Resene Lustacryl D310, Waterborne Enamel

Note: Cedar requires a solvent based Alkyd primer to avoid tannin staining issues.

Where a Gloss finish is required substitute 3rd & 4th coats with:

3rd coat:

Resene Enamacryl D309, Waterborne Enamel

4th coat:

Resene Enamacryl D309, Waterborne Enamel

Where a Low sheen finish is required substitute 3rd & 4th coats with:

3rd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

4th coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

4.25
NEW INTERIOR TIMBER DOORS, JOINERY, SKIRTING – CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/1

1st coat

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Where Gloss finish is required substitute 1st, 2nd & 3rd coats with:

1st coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 1st, 2nd & 3rd coats with:

1st coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

2nd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

3rd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4.26
NEW INTERIOR TIMBER DOORS, JOINERY, SKIRTING – STAIN

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/1

1st coat

Resene Colorwood D50a, Waterborne Natural Wood stain

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Where Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

3rd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4th coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4.27
NEW INTERIOR TIMBER WALLS, PARTICLE BOARD, MDF, PLYWOOD

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 14/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

Where a Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a standard acrylic finish is required (dry areas only) substitute 2nd & 3rd coats with:

2nd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

3rd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

Where a Clinical finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene ClinicalCote D318, Satin Acrylic

3rd coat:

Resene ClinicalCote D318, Satin Acrylic

4.28
NEW INTERIOR TIMBER CEILINGS, PARTICLE BOARD, MDF, PLYWOOD

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 14/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where a Low sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

4.29
NEW INTERIOR TIMBER WALLS/CEILINGS, PARTICLE BOARD, MDF, PLYWOOD – CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/1

1st coat

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Note: this section is not intended for substrates within NZ Building Code E3 Internal Moisture – E3/AS1 3.0 Watersplash zone.

Where Gloss finish is required substitute 1st, 2nd & 3rd coats with:

1st coat

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 1st, 2nd & 3rd coats with:

1st coat

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

2nd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

3rd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4.30
NEW INTERIOR TIMBER WALLS/CEILINGS; PARTICLE BOARD, MDF, PLYWOOD - STAIN

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/1

1st coat

Resene Colorwood D50a, Waterborne Natural Wood stain

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Note: this section is not intended for substrates within NZ Building Code E3 Internal Moisture – E3/AS1 3.0 Watersplash zone.

Where Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

3rd coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4th coat:

Resene Aquaclear Semi-Gloss D59, WB Urethane Varnish

4.31
NEW INTERIOR TIMBER WALLS/CEILINGS; PARTICLE BOARD, MDF, PLYWOOD - WHITEWASH

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/1

1st coat

Resene Colorwood Whitewash D50W, Waterborne Urethane

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Note: this section is not intended for substrates within NZ Building Code E3 Internal Moisture – E3/AS1 3.0 Watersplash zone

Where Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

3rd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

4th coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane

3rd coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane

4th coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane

4.32
NEW INTERIOR TIMBER FLOOR

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 12/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Walk-On Flooring & Paving Paint D322, Waterborne

3rd coat:

Resene Walk-On Flooring & Paving Paint D322, Waterborne

4th coat:

Resene Concrete Wax D508, Waterborne Satin Glaze

Where a semi-gloss  finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

4.33
NEW INTERIOR TIMBER FLOOR – LOW VOC 2 PACK URETHANE

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 12/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Uracryl 802 RA55W, Low VOC Semi Gloss Urethane (NEC)

3rd coat:

Resene Uracryl 802 RA55W, Low VOC Semi Gloss Urethane (NEC)

Note: Allow Resene Quick Dry to dry for 24 hours prior to applying Resene Uracryl 802

4.34
NEW INTERIOR TIMBER FLOOR - CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 11/1

1st coat

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

2nd coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

3rd coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

For High Foot Traffic areas add additional coat:

4th coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

4.35
NEW INTERIOR TIMBER FLOOR – STAIN & CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 11/1

1st coat

Resene Colorwood D50a, Natural Wood Stain

2nd coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

3rd coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

4th coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

For High Foot Traffic areas add additional coat:

5th coat:

Resene Qristal ClearFloor 1K, D506 Waterborne Flooring Urethane

Environmental interior timber - Existing
4.36
EXISTING INTERIOR TIMBER DOORS, JOINERY, SKIRTING

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 9/3

Spot Prime:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

1st coat:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Enamacryl D309, Waterborne Enamel

3rd coat:

Resene Enamacryl D309, Waterborne Enamel

Where a Low sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

4.37
EXISTING INTERIOR TIMBER DOORS, JOINERY, SKIRTING; CEDAR

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 9/3

Spot Prime:

Resene Enamel Undercoat D44, Solvent-borne Undercoat (NEC)

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Notes:

1. This section assumes the existing coating is enamel (which must be thoroughly abraded).

2. Cedar requires a solvent based Alkyd primer to avoid tannin staining issues.

Where a Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Enamacryl D309, Waterborne Enamel

3rd coat:

Resene Enamacryl D309, Waterborne Enamel

Where a Low sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low sheen D311, Waterborne Enamel

4.38
EXISTING INTERIOR TIMBER DOORS, JOINERY, SKIRTING – CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/3

1st coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

2nd coat::

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Where Gloss finish is required substitute 1st, 2nd coats with:

1st coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 1st, 2nd coats with:

1st coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane Varnish

4.39
EXISTING INTERIOR TIMBER WALLS, PARTICLE BOARD, MDF, PLYWOOD

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 14/3

Spot Prime:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

1st coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

Where a Flat finish is required substitute 1st & 2nd coats with:

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where a Semi-Gloss finish is required substitute 1st & 2nd coats with:

1st coat:

Resene Lustacryl D310, Waterborne Enamel

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a standard acrylic finish (dry areas only) is required substitute 1st & 2nd coats with:

1st coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

2nd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

Where a Clinical finish is required substitute 1st & 2nd coats with:

1st coat:

Resene ClinicalCote D318, Satin Acrylic

2nd coat:

Resene ClinicalCote D318, Satin Acrylic

4.40
EXISTING INTERIOR TIMBER CEILINGS, PARTICLE BOARD, MDF, PLYWOOD

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 14/3

Spot Prime:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where a Low sheen finish is required substitute 1st & 2nd coats with:

1st coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene Spacecote Low Sheen D311, Waterborne Enamel

Where a Clinical finish is required substitute 1st & 2nd coats with:

1st coat:

Resene ClinicalCote D318, Satin Acrylic

2nd coat:

Resene ClinicalCote D318, Satin Acrylic

4.41
EXISTING INTERIOR TIMBER WALLS, CEILINGS, PARTICLEBOARD, MDF, PLYWOOD – CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 10/3

1st coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Satin D59, Waterborne Urethane Varnish

Where Gloss finish is required substitute 1st, 2nd coats with:

1st coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Gloss D59, Waterborne Urethane Varnish

Where Semi-Gloss finish is required substitute 1st, 2nd coats with:

1st coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane Varnish

2nd coat:

Resene Aquaclear Semi-Gloss D59, Waterborne Urethane Varnish

4.42
EXISTING INTERIOR TIMBER FLOOR – SINGLE PACK, CLEAR COAT

Surface Prep:

Resene SIPDS No2 and Spec Sheet 2: 11/3

1st coat:

Resene Qristal ClearFloor 1K D506, Waterborne Flooring Urethane

2nd coat:

Resene Qristal ClearFloor 1K D506, Waterborne Flooring Urethane

3rd coat:

Resene Qristal ClearFloor 1K D506, Waterborne Flooring Urethane

Note: Use this system for Low/Medium traffic. For high traffic use contact your Resene Architectural Representative.

Where extra durability is required add 4th coat:

4th coat

Resene Qristal ClearFloor 1K D506, Waterborne Flooring Urethane

Interior fibre cement - new
4.43
NEW INTERIOR FIBRE CEMENT WALLS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Where Flat finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

4.44
NEW INTERIOR FIBRE CEMENT WALLS - CLINICAL DRY AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene ClinicalCote Satin D318, Waterborne

3rd coat:

Resene ClinicalCote Satin D318, Waterborne

Where a Low Sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

3rd coat:

Resene ClinicalCote Low Sheen D318, Waterborne

4.45
NEW INTERIOR FIBRE CEMENT WALLS - CLEAR COAT

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

2nd coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

Where Flat finish is required substitute 2nd & 3rd coats only with:

2nd coat:

Resene Concrete Clear - Flat D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Flat D54a, Waterborne Clear

Where Satin finish is required substitute 2nd & 3rd coats only with:

2nd coat:

Resene Concrete Clear - Satin D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Satin D54a, Waterborne Clear

4.46
NEW INTERIOR FIBRE CEMENT CEILINGS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

4.47
NEW INTERIOR FIBRE CEMENT CEILINGS; CLINICAL DRY AREAS HEALTHCARE

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene ClinicalCote Low-Sheen D318, Waterborne

3rd coat:

Resene ClinicalCote Low-Sheen D318, Waterborne

Where a Satin finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene ClinicalCote Satin D318, Waterborne

3rd coat:

Resene ClinicalCote Satin D318, Waterborne

4.48
NEW INTERIOR FIBRE CEMENT CEILINGS - CLEAR COAT

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

2nd coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Gloss D54a, Waterborne Clear

Where Flat finish is required substitute 2nd & 3rd coats only with:

2nd coat:

Resene Concrete Clear - Flat D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Flat D54a, Waterborne Clear

Where Satin finish is required substitute 2nd & 3rd coats only with:

2nd coat:

Resene Concrete Clear - Satin D54a, Waterborne Clear

3rd coat:

Resene Concrete Clear - Satin D54a, Waterborne Clear

Environmental Interior fibre cement - existing
4.49
EXISTING INTERIOR FIBRE CEMENT WALLS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/3

Spot Prime:

Resene Concrete Primer D405, Acrylic Concrete Primer

1st coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Note: Assumes existing coating is acrylic.

Where Flat finish is required substitute 1st & 2nd coats with:

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

4.50
EXISTING INTERIOR FIBRE CEMENT CEILINGS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/3

Spot Prime:

Resene Concrete Primer D405, Acrylic Concrete Primer

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Environmental interior masonry/cementitious – new
4.51
NEW INTERIOR INSITU CONCRETE, PRECAST, BLOCKS; WALLS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Where Flat finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a standard acrylic finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

3rd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

4.52
NEW INTERIOR INSITU CONCRETE, PRECAST, BLOCKS; CEILINGS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/1

1st coat

Resene Concrete Primer D405, Acrylic Concrete Primer

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

3rd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where Low Sheen is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Where Semi-Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a standard acrylic Flat finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Ceiling Paint D305, Flat Acrylic

3rd coat:

Resene Ceiling Paint D305, Flat Acrylic

4.53
NEW INTERIOR CONCRETE FLOOR – SINGLE PACK

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 7/1

1st coat

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Walk-On Flooring & Paving Paint – D322, Waterborne

3rd coat:

Resene Walk-On Flooring & Paving Paint – D322, Waterborne

4th coat:

Resene Concrete Wax – D508, Waterborne Satin Glaze

Note: This system is not suitable for garage floors.

Where a Semi-Gloss finish is required substitute 2nd, 3rd & 4th coats with:

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Waterborne Enamel

4.54
NEW INTERIOR CONCRETE FLOOR – SINGLE PACK, CLEAR COAT

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 7/1

1st coat:

Resene Concrete Wax – D508, Waterborne Satin Glaze

2nd coat:

Resene Concrete Wax – D508, Waterborne Satin Glaze

3rd coat:

Resene Concrete Wax – D508, Waterborne Satin Glaze

4th coat:

Resene Concrete Wax – D508, Waterborne Satin Glaze

Note: This system is not suitable for garage floors.

4.55
NEW INTERIOR CONCRETE FLOOR, GARAGE FLOOR - LOW VOC 2 PACK EPOXY

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 7/1

Sealer coat

Resene ArmourBond - RA408, Clear Low VOC Epoxy Sealer (NEC)

1st coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

2nd coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

3rd coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

Note: Where a “Non-Skid” system is required modify 2nd coat only with 2kg of Resene SRG per 4L mix

Where a Gloss finish is required substitute 1st, 2nd, & 3rd coats with:

1st coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

2nd coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

3rd coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

4.56
NEW INTERIOR CONCRETE FLOOR – LOW VOC 2 PACK EPOXY

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 7/1

Sealer coat

Resene ArmourBond - RA408, Clear Low VOC Epoxy Sealer (NEC)

1st coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

2nd coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

3rd coat:

Resene Aquapoxy Semi Gloss – RA43, WB Low VOC Epoxy (NEC)

Note: Where a “Non-Skid” system is required modify 2nd coat only with 2kg of Resene SRG per 4L mix

Where a Gloss finish is required substitute 1st, 2nd, & 3rd coats with:

1st coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

2nd coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

3rd coat:

Resene Aquapoxy Gloss – RA43, WB Low VOC Epoxy (NEC)

Environmental interior masonry/cementitious – existing
4.57
EXISTING INTERIOR INSITU CONCRETE, PRECAST, BLOCKS; WALLS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/3

Spot Prime:

Resene Concrete Primer D405, Acrylic Concrete Primer

1st coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

Where a flat finish is required substitute 1st & 2nd coats with:

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where semi-gloss finish is required substitute 1st & 2nd coats with

1st coat:

Resene Lustacryl D310, Waterborne Enamel

2nd coat:

Resene Lustacryl D310, Waterborne Enamel

Where a standard acrylic finish is required substitute 1st & 2nd coats with

1st coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

2nd coat:

Resene Zylone Sheen D302, Low Sheen Acrylic

4.58
EXISTING INTERIOR INSITU CONCRETE, PRECAST, BLOCKS; CEILINGS

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 6/3

Spot Prime:

Resene Concrete Primer D405, Acrylic Concrete Primer

1st coat:

Resene SpaceCote Flat D314, Waterborne Enamel

2nd coat:

Resene SpaceCote Flat D314, Waterborne Enamel

Where a low sheen finish is required substitute 1st & 2nd coats with:

1st coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

4.59
EXISTING INTERIOR CONCRETE FLOOR, GARAGE FLOOR - LOW VOC 2 PACK EPOXY

Surface Prep:

Resene SIPDS No3 and Spec Sheet 3: 7/3

Spot Prime:

Resene ArmourBond - RA408, Clear Epoxy Sealer (NEC)

1st coat:

Resene Aquapoxy Gloss – RA43, Waterborne Epoxy (NEC)

2nd coat:

Resene Aquapoxy Gloss – RA43, Waterborne Epoxy (NEC)

Note: suitable for garage floors.  Assumes existing coating is a 2 pack Epoxy/Urethane

Where a semi-gloss finish is required substitute 1st & 2nd coats with:

1st coat:

Resene Aquapoxy Semi-Gloss – RA42, Waterborne Epoxy (NEC)

2nd coat:

Resene Aquapoxy Semi-Gloss – RA42, Waterborne Epoxy (NEC)

Environmental Interior Metal – new
4.60
NEW INTERIOR ZINC / GALVANISED STEEL - SINGLE PACK DECORATIVE

Surface Prep:

Resene SIPDS No4 and Spec Sheet 4: 6/1

1st coat

Resene Galvo Prime D402, Waterborne Galv steel primer (NEC)

2nd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

Where a Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Enamacryl D309, Gloss Waterborne Enamel

3rd coat:

Resene Enamacryl D309, Gloss Waterborne Enamel

Where a Low Sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

For Resene High Performance 2 pack type systems refer to MasterSpec 6745R

4.61
NEW INTERIOR SHOP PRIMED MILD STEEL - SINGLE PACK DECORATIVE

Surface Prep:

Resene SIPDS No4 and Spec Sheet 4: 5/1

1st coat:

Resene Galvo Prime D402, Waterborne Galv steel primer (NEC)

2nd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

Where a Gloss finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene Enamacryl D309, Gloss Waterborne Enamel

3rd coat:

Resene Enamacryl D309, Gloss Waterborne Enamel

Where a Low Sheen finish is required substitute 2nd & 3rd coats with:

2nd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

3rd coat:

Resene SpaceCote Low Sheen D311, Waterborne Enamel

For Resene High Performance 2 pack type systems refer to MasterSpec 6745R

Environmental Interior Metal – existing
4.62
EXISTING INTERIOR GALVANISED or MILD STEEL - SINGLE PACK DECORATIVE

Surface Prep:

Resene SIPDS No4 and Spec Sheet 4: 5/3 & 4: 6/3

Spot Prime:

Resene GP Metal Primer D411, General Purpose Modified Alkyd (NEC)

1st coat:

Resene Quick Dry D45, Waterborne Acrylic Primer Undercoat

2nd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

3rd coat:

Resene Lustacryl D310, Semi-Gloss Waterborne Enamel

Note: This section assumes the existing coating is enamel (which must be thoroughly abraded)