Masterspec
31 Mar 2026
Masterspec Specified: 211 High Street by Ignite
211 High Street transforms the iconic Excelsior Hotel site into a high-quality, sustainable, commercial mixed-use building. The ground floor features...
25 Mar 2026
Why AI Changes How We Trust Construction Specifications
AI has not created the risk of inaccurate or misused construction specifications, but it has made that risk faster, easier to scale, and harder to...
04 Mar 2026
2025 Building Code Update and Building Product Specifications
On 28th July 2025, MBIE's Building Product Specifications (BPS) document came into effect. This document, to be read alongside the Acceptable...
19 Nov 2025
Masterspec Specified: Te Pae Christchurch Convention Centre
Te Pae Christchurch Convention Centre stands as a landmark civic and cultural facility in the heart of Christchurch, New Zealand. Designed by Woods...
15 Oct 2025
Masterspec Specified: Air New Zealand Hangar 4 by Studio Pacific Architecture
The project was designed to meet Green Star environmental standards and includes advanced cladding, roofing, and mechanical systems tailored for...
10 Oct 2025
Bridging the Gap: Empowering Better Specifications for Builders
At this year’s Constructive Conference in Auckland, we asked every delegate we spoke with: “What can we do to improve construction documentation and...
24 Sep 2025
NECO₂ – New Zealand’s Embodied Carbon Repository Goes Live
New Zealand’s construction sector has taken a major step providing New Zealand-centric carbon data with the launch of the first release of NECO₂ – the...
22 Sep 2025
Masterspec Specified: Award Winning Bryndwr House One by AO Architecture
Tucked into a secluded rear site behind a mature, tree-lined driveway in leafy Bryndwr, this new family home forms one half of a pair of residences...
22 Sep 2025
Masterspec Specified: Award Winning Flockhill Sugarloaf by Hierarchy Group
Nestled in the remote Craigieburn Valley of New Zealand’s Southern Alps, Sugarloaf at Flockhill is more than a restaurant — it’s an architectural...
12 Sep 2025
Masterspec Specified: Award Winning He Whare Hono ō Tūwharetoa by DCA Architects of Transformation
In the heart of Taupō, a landmark civic building is redefining the relationship between architecture, culture, and governance.
08 Sep 2025
Masterspec Specified: Award Winning Terrace 12C by Bassett-Smith Architecture
Terrace 12C is a residential development located in Tauranga, designed to maximise site efficiency while maintaining architectural individuality. The...
08 Sep 2025
Masterspec Specified: Award Winning Miller Residences by Oliver Andrew Associates
In the heart of Auckland, the Miller Residences by Oliver Andrew Associates stand as a refined example of contemporary multi-unit housing — where...
01 Apr 2025
Document Referencing and Scheduling with eCert
Our editor team has updated all Masterspec work sections which have references to environmental documents. Where environmental document references...
27 Mar 2025
Update Manager New Features
The new Update Manager features are designed to boost productivity when applying changes to updated work sections. Simplify work section updates with...
03 Mar 2025
CIL is Now Accepting Product Carbon Data for the National Embodied Carbon Data Repository for Construction.
CIL Masterspec is now accepting carbon information in the form of Environmental Product Declarations (EPDs) or Life Cycle Assessments (LCAs) from...
06 Jan 2025
Carbon 2025 and Beyond: Building a More Sustainable Future for NZ Construction
In July 2024, Construction Information Ltd (CIL) and the Building Research Association of New Zealand (BRANZ) announced a partnership to develop a...
01 Nov 2024
Introducing eCert: A Game-Changing Tool for Sustainable Construction
As the New Zealand construction industry increasingly focuses on sustainability and carbon reduction, there is a growing need for tools that can help...
26 Sep 2024
Masterspec Specified: Manawa House by Cube Architecture
"Masterspec has been an indispensable tool for our project Manawa House. During the specification, Masterspec streamlined our entire specification...
26 Sep 2024
Masterspec Specified: Award Winning Ligar Bay Bach by Young Architects
"Masterspec was used for providing a detailed, fully customised, specification as part of our comprehensive project documentation for the Ligar Bay...
25 Sep 2024
Masterspec Specified: Hilltop Home by Jon McAlpine Architecture
“Masterspec is a critical component in our studio. Its user-friendly platform and regular product specification updates, keep us constantly on the...

AMPS MATTER WITH ELECTRICAL APPLIANCES

30 Jan 2019

Imagine the common scenario where the home owner selects and supplies the all-electric cooking appliance late in the project. The designer had provided them the physical dimensions allowed for the appliance, which the owners had duly used. However, at the finishing stages of the project the cooking appliance arrives but is found to be a much higher amperage than has been allowed for. If the appliance must be used, then what are the ramifications? Well the supply cable and the MCB may have to be replaced by larger ones capable of handling the higher amperage. In extreme cases it could even mean replacing the electrical main into the house (possibly also affecting the meter and DB).

This scenario is not an everyday occurrence, but according to some of our Masterspec users it has happened. And it is not restricted to cooking appliances, it could be high amperage water heaters, space heaters, air conditioning, etc, or the cumulative effect of a number of these types of appliances.

In this article we will give a background of amps, cables and mains for house designers. It won't get too technical as that can get very complicated for the non-specialist. But it may give you a feel as to when you need to consult an Electrical Engineer etc.

What are AMPS?

The electrical terms you may be familiar with are Volts (V), current (I), resistance (R) and electrical power (P). Current (I) is measured in Amps, resistance (R) is measured in ohms and power (P) is measured in Watts. There are a number of mathematical equations that allow these various elements to be manipulated. But with normal power supply voltage is fixed to approximately 240V.

Roughly speaking, electrical cables have resistance which consumes power which increases the current, which produces heat in the cable. Too much heat without the ability to vary the voltage usually leads to the need for bigger (or more) cables to allow increase current and reduce heat.

Relax, that’s the hard bit over!  What it basically means is, a high wattage high amperage appliance may need a bigger cable to squeeze the current through and deal with the heat.

Cable size

The allowable maximum temperature for cables depends on the insulation. Standard thermoplastic insulation (TPS) has a maximum temperature of 75°C while high temperature insulation (like X-90, R-HF-90 etc) can get up to 90°C or 105°C. High temperatures due to Amperage can be made worse by reducing the ability of the cable to lose heat, by enclosing it (particularly in insulation) or exposing it to a high ambient temperature (e.g. a hot roof space). Bundling (bunching) cables also means the cables can add heat to each other.

The Standard AS/NZS 3000:2007 (or 2018), Electrical Installations (known as the Australian/New Zealand Wiring Rules), Table C5 (or C6 in 2018) for example gives the relationship between cable sizes and amperages relative to enclosure situations (for V-90 cable). AS/NZS 3008.1.2 Electrical Installations - Selection Of Cables - Cables For Alternating Voltages Up To And Including 0.6/1 Kv - Typical New Zealand Installation Conditions, provides more examples and detail on cable sizing.

So for example Masterspec Electrical Standard says that the minimum cable sizes for  an average Range (cooking appliance) circuit should be:

  • Single phase: 6mm² high temperature cable on 32 amp MCBs

From AS/NZS 3000:2007 Table 5, a 6mm² cable (V-90) against the back of the lining in an insulated wall would handle 32 amps. AS/NZS 3008.1.2 in its tables for higher temperature cables would allow the appropriate cable to be in the middle of the insulation. If the appliance needed more than 32A a larger cable may be required or where the cable is run may have to be changed. Conversely a lesser amperage may allow a smaller cable, or the type of cable and where it is run may be less critical.

Phase

Most houses (and home appliances) use Single Phase supply and distribution with a minimum rating of 60 amps on supply. Heavy commercial and industrial users (and some equipment) often use 3 Phase (or 2 Phase) supply still at 60 amps per phase and single and/or 3 Phase distribution. Except for cable structure and size, the differences between the two are too complex for this article, other than due to the efficiency of 3 Phase you get 3 times the power for 1.5 times more cable.

A few houses with very high demand (over 60 amps) need 2 or 3 Phase supply, usually with (but not limited to) single Phase distribution.

Just over 60 amps is the normal limit for a single phase.

High demand appliances

High demand electrical appliance could be; large cooking appliances, large storage hot water heaters, high volume instantaneous water heaters, electric vehicle fast chargers, large central air-conditioning systems, etc. Although not common, an owner may want 3 Phase appliances or other equipment (e.g. commercial grade workshop tools).

The maximum demand of an appliance on any phase at any one time is complex to calculate, it would have to be obtained from the manufacturer, which is not always easy. Cooking appliance are made slightly easier by AS/NZS 3000:2007 Table 4 (Table 5 2018), which compares the cooking appliance full-load energy rating (Watts) to the maximum Amps demand.

For instance:

  • 1000W to 1300W = 32A
  • Over 1300W = 40A

A normal house is generally not an issue when it comes to total demand and the main supply, but for a high demand house calculating the total demand for the whole house is very complex (it is not a simple addition) and should only be attempted by specialists. Potentially a high demand house may need more than a Single Phase mains supply.

Project requirements

Ensure that you know if selected appliances are low or high demand, and if the client is to supply them, ensure they know the limitations.  If in doubt seek professional advice.

Masterspec Sections

Masterspec has added brief guidance, along the lines of this article, to the Electrical Standard and Basic sections to act as a reminder.