{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Subscribe
LOG IN
✖
Select Relevant Account
Select yourself to see only your informmation.
Select an organisation to manage it as well.
✖
Login
25 characters limit applied!
Remember Me
Forgot password?
Create an Account
By accessing or using the Website, you acknowledge
and agree that you have read and understand all of
the terms and conditions. From time to time we may
update the terms of our agreement (Terms) with you
for the provision of the Services and access to our
Website. Our Terms were last updated on the
16.09.2023
and can be
accessed here.
≡
≡
MENU ☰
PRODUCTS
Masterspec Libraries
Overview
Standard
Basic
Minor
Structural & Civil
SCNZ Structural
Services
Landscapes
Interiors
Compare Libraries
Online Workspace
Online Workspace
Standards Online Changes
Keynotes
MasterKey
MasterKey On ArchiCAD
MasterKey On Revit
Download MasterKey for Revit
Subscribe
Join Online
Price Calculator
Options Explained
Free 30 Day Trial
MasterKey Fee Schedule
TRAINING
Workshops
Specifier Training Events
mDocs
Welcome to mDocs
mDocs Training Videos
Writing Specifications
Specifier Documentation
Specification Training Videos
Editor Video Series
Office Masters
Office Masters Documentation
MasterKey
Tutorials - Revit
Tutorials - ArchiCAD
MasterKey Training Videos
Other Services
Online NZCIC Training Series
RESOURCES
BIM at Masterspec
BIM Resources
Open BIM Object standard
Properties Selector
NZAMS
BIM Survey
Download MasterKey for Revit
Technical Resources
Overview
Changes to H1 2022
Archived Technical Videos
CBI Overview
Other Resources
NZCIC Guidelines
DINZ
LBP Cert of Design
Masterspec Project Forms
Spec Authentication
NEWS
News
Search Articles
Read Masterspec NOTES
Masterspec Updates
SUPPLIERS
Supplier Opportunities
Supplier Overview
Partner Experience
Overview
PBI Height Safety
Allproof Industries
ABOUT
Masterspec
About CIL
Our Mission
Masterspec History
Client Testimonials
Support
FAQs
Support
Contact Us
News
Search Articles
Read Masterspec NOTES
Masterspec Updates
Latest Stories
26 Sep 2024
Masterspec Specified: Manawa House by Cube Architecture
"Masterspec has been an indispensable tool for our project Manawa House. During the specification, Masterspec streamlined our entire specification...
26 Sep 2024
Masterspec Specified: Award Winning Ligar Bay Bach by Young Architects
"Masterspec was used for providing a detailed, fully customised, specification as part of our comprehensive project documentation for the Ligar Bay...
25 Sep 2024
Masterspec Specified: Hilltop Home by Jon McAlpine Architecture
“Masterspec is a critical component in our studio. Its user-friendly platform and regular product specification updates, keep us constantly on the...
06 Aug 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
In Masterspec NOTES June 2024, we provided commentary around the changes to the NZ Building Code relating to domestic smoke alarms.
18 Jul 2024
New Industry Initiative to Reduce Carbon Emissions of New Zealand Buildings
A new industry-led initiative aims to reduce the environmental impact of Aotearoa New Zealand’s buildings, which contribute up to 20% of the national...
04 Jul 2024
Masterspec Announces New MasterKey4 for Revit 2025 Enhancements
Streamlined Workflows and Improved Collaboration with MasterKey4. We are excited to announce the latest update to MasterKey4 for Revit 2025, designed...
04 Jun 2024
Building Code Updates 2023-2024
This month we have published amendments in response to building code updates. The 2023-24 NZBC changes were published by MBIE on the 2 November 2023,...
04 Jun 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
From November 2023 the Building Code Acceptable Solutions for Protection from Fire (C/AS1 and C/AS2) have been amended to make Type 1 interconnected...
05 Apr 2024
Understanding Project Scope and How to Specify Window Systems
It is vital that Movement and Deflection criteria are correctly defined in the Specification. We cannot over emphasize the importance of correctly...
04 Apr 2024
MBIE Building Consent System Review - Overview and Update
In July 2022, MBIE commenced a review of the building consent system, as part of the Building System Reforms to improve the consenting process. The...
30 Nov 2023
NZCIC Guidelines Responsibility Schedule Goes Digital
The new online tool enables real-time collaboration among multiple stakeholders, fostering efficiency and innovation in construction processes.
10 Nov 2023
BCA Requests to Modify Manufacturers Technical Content
mDocs allows the specifier to quickly access the latest version of a document uploaded by the manufacturer or supplier. Importantly, these detailed...
27 Sep 2023
Masterspec Specified: Award Winning Taharoto Lane by X Studio Architects
The development will have 19 units, including studio, office, and retail space. The residential units will have balconies with views of the city...
27 Sep 2023
Masterspec Specified: Award Winning Soaring Box House by Turner Road Architecture
The house’s unique design fits into the rural landscape. The house has a cantilevered structure and a soaring angular volume. The interior design is...
13 Sep 2023
Hallmark Group Opens Up About BPIR
Recently, Hallmark Group turned to Masterspec, a trusted name in compliance solutions, for guidance on their BPIR for fire doors. In this article, we...
06 Sep 2023
Al Bahr Towers in Abu Dhabi: Kinetic Architecture, Innovation and Sustainability
In the heart of Abu Dhabi's skyline, two iconic towers stand as shining examples of innovative architecture and sustainable design. The Al Bahr...
05 Sep 2023
Silica - Understanding the Risks
Over recent months, we have had several enquiries from designers in relation to industry concerns with silica-based building products and the...
18 Aug 2023
Masterspec: Your Partner in BPIR Product Review Compliance
The Building Regulation Act 2022 comes into force on 11th December 2023, requiring building product suppliers in New Zealand to provide baseline...
27 Jul 2023
Masterspec Partners with NZCIC & CSA to Digitise the NZCIC Guidelines
Masterspec, has been working with the New Zealand Construction Industry Council (NZCIC) and the Construction Sector Accord (CSA) in an exciting new...
24 Jul 2023
How Specifiers Reduce Risks by using Masterspec's Work Section Support
In the construction industry, collaboration is one of the keys to success. Masterspec, as a leader in providing specification solutions, has long...
Prev
Next
AMPS MATTER WITH ELECTRICAL APPLIANCES
24 Sep 2021
Close
Image 1 of 1
Maximize image
Restore image
Imagine the common scenario where the home owner selects and supplies the all-electric cooking appliance late in the project. The designer had provided them the physical dimensions allowed for the appliance, which the owners had duly used. However, at the finishing stages of the project the cooking appliance arrives but is found to be a much higher amperage than has been allowed for. If the appliance must be used, then what are the ramifications? Well the supply cable and the MCB may have to be replaced by larger ones capable of handling the higher amperage. In extreme cases it could even mean replacing the electrical main into the house (possibly also affecting the meter and DB).
This scenario is not an everyday occurrence, but according to some of our Masterspec users it has happened. And it is not restricted to cooking appliances, it could be high amperage, EV chargers, water heaters, space heaters, air conditioning, etc, or the cumulative effect of a number of these type of appliances.
In this article we will give a background of amps, cables and mains for house designers. It won't get too technical as that can get very complicated for the non-specialist. But it may give you a feel as to when you need to consult an Electrical Engineer etc.
What are AMPS
The electrical terms you may be familiar with are Volts (V), current (I), resistance (R) and electrical power (P). Current (I) is measured in Amps, resistance (R) is measured in ohms and power (P) is measured in Watts.
There are a number of mathematical equations that allow these various elements to be manipulated. But with normal power supply voltage is fixed to approximately 240V. Roughly speaking, electrical cables have resistance which consumes power which increases the current, which produces heat in the cable. Too much heat without the ability to vary the voltage usually leads to the need for bigger (or more) cables to allow increased current and a reduction in heat.
Relax, that’s the hard bit over! What it basically means is, a high wattage high amperage appliance may need a bigger cable to squeeze the current through and deal with the heat.
Cable size
The allowable maximum temperature for cables depends on the cable insulation. Standard thermoplastic insulation (TPS) has a maximum temperature of 75°C while high temperature insulation (like X-90, R-HF-90 etc) can get up to 90°C or 105°C. High temperatures due to Amperage can be made worse by reducing the ability of the cable to lose heat, by enclosing it (particularly in building insulation) or exposing it to a high ambient temperature (e.g. a hot roof space). Bundling (bunching) cables also means the cables can add heat to each other.
The Standard AS/NZS 3000:2007 (or 2018), Electrical Installations (known as the Australian/New Zealand Wiring Rules), Table C5 (or C6 in 2018) for example gives the relationship between cable sizes and amperages relative to enclosure situations (for V-90 cable). AS/NZS 3008.1.2 Electrical Installations - Selection Of Cables - Cables For Alternating Voltages Up To And Including 0.6/1 Kv - Typical New Zealand Installation Conditions, provides more examples and detail on cable sizing.
For example, Masterspec ELECTRICAL STANDARD says that the minimum cable sizes for an average Range (cooking appliance) circuit should be
Single phase: 6mm² high temperature cable on 32-amp MCBs.
From AS/NZS 3000:2007 Table 5, a 6mm² cable (V-90) against the back of the lining in an insulated wall would handle 32 amps. AS/NZS 3008.1.2 in its tables for higher temperature cables would allow the appropriate cable to be in the middle of the insulation. If the appliance needed more than 32A a larger cable may be required or where the cable is run may have to be changed. Conversely a lesser amperage may allow a smaller cable, or the type of cable and where it is run may be less critical.
Phase
Most houses (and home appliances) use Single Phase supply and distribution with a minimum rating of 60 amps on supply. Heavy commercial and industrial users (and some equipment) often use 3 Phase (or 2 Phase) supply still at 60 amps per phase and single and/or 3 Phase distribution. Except for cable structure and size, the differences between the two are too complex for this article, other than due to the efficiency of 3 Phase, you get 3 times the power for 1.5 times more cable.
A few houses with very high demand (over 60 amps) need 2 or 3 Phase supply, usually with (but not limited to) single Phase distribution. Just over 60 amps is the normal limit for a single phase.
High demand appliances
High demand electrical appliance could be;
large cooking appliances (pyrolytic ovens, induction hobs)
large storage hot water heaters
high volume instantaneous water heaters
electric vehicle fast chargers
large central air-conditioning systems, etc.
Although not common, an owner may want 3 Phase appliances or other equipment (e.g., commercial grade workshop tools).
The maximum demand of an appliance on any phase at any one time is complex to calculate, it would have to be obtained from the manufacturer, which is not always easy. Cooking appliances are made slightly easier by AS/NZS 3000:2007 Table 4 (Table 5 2018), which compares the cooking appliance full-load energy rating (Watts) to the maximum Amps demand.
For instance:
1000W to 1300W = 32A
Over 1300W = 40A
A normal house is generally not an issue when it comes to total demand and the main supply, but for a high demand house calculating the total demand for the whole house is very complex (it is not a simple addition) and should only be attempted by specialists. Potentially a high demand house may need more than a Single-Phase mains supply.
Future proofing
Future proofing your project is complicated enough but throw into the mix the ongoing development of EV cars, and it becomes very difficult. Who knows how EV cars and chargers will develop over the next decade? A single fast charger currently may require say 30 amps but will two be required and is that on top of a pyrolytic oven, a steam oven and a large induction hob? The amps start to pile up, probably more than a single phase (60 amps). Although very few of us have a crystal ball, it is a worthy discussion to have with your clients.
Project requirements
Ensure that you know if selected appliances are low or high demand, and if the client is to supply them, ensure they know the limitations. If in doubt seek professional advice.
Masterspec Sections
Masterspec has added brief guidance, along the lines of this article, to the Electrical Standard and Basic sections to act as a reminder.
Prev
Next