Masterspec
01 Apr 2025
Document Referencing and Scheduling with eCert
Our editor team has updated all Masterspec work sections which have references to environmental documents. Where environmental document references...
27 Mar 2025
Update Manager New Features
The new Update Manager features are designed to boost productivity when applying changes to updated work sections. Simplify work section updates with...
03 Mar 2025
CIL is Now Accepting Product Carbon Data for the National Embodied Carbon Data Repository for Construction.
CIL Masterspec is now accepting carbon information in the form of Environmental Product Declarations (EPDs) or Life Cycle Assessments (LCAs) from...
06 Jan 2025
Carbon 2025 and Beyond: Building a More Sustainable Future for NZ Construction
In July 2024, Construction Information Ltd (CIL) and the Building Research Association of New Zealand (BRANZ) announced a partnership to develop a...
01 Nov 2024
Introducing eCert: A Game-Changing Tool for Sustainable Construction
As the New Zealand construction industry increasingly focuses on sustainability and carbon reduction, there is a growing need for tools that can help...
26 Sep 2024
Masterspec Specified: Manawa House by Cube Architecture
"Masterspec has been an indispensable tool for our project Manawa House. During the specification, Masterspec streamlined our entire specification...
26 Sep 2024
Masterspec Specified: Award Winning Ligar Bay Bach by Young Architects
"Masterspec was used for providing a detailed, fully customised, specification as part of our comprehensive project documentation for the Ligar Bay...
25 Sep 2024
Masterspec Specified: Hilltop Home by Jon McAlpine Architecture
“Masterspec is a critical component in our studio. Its user-friendly platform and regular product specification updates, keep us constantly on the...
06 Aug 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
In Masterspec NOTES June 2024, we provided commentary around the changes to the NZ Building Code relating to domestic smoke alarms.
18 Jul 2024
New Industry Initiative to Reduce Carbon Emissions of New Zealand Buildings
A new industry-led initiative aims to reduce the environmental impact of Aotearoa New Zealand’s buildings, which contribute up to 20% of the national...
04 Jul 2024
Masterspec Announces New MasterKey4 for Revit 2025 Enhancements
Streamlined Workflows and Improved Collaboration with MasterKey4. We are excited to announce the latest update to MasterKey4 for Revit 2025, designed...
04 Jun 2024
Building Code Updates 2023-2024
This month we have published amendments in response to building code updates. The 2023-24 NZBC changes were published by MBIE on the 2 November 2023,...
04 Jun 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
From November 2023 the Building Code Acceptable Solutions for Protection from Fire (C/AS1 and C/AS2) have been amended to make Type 1 interconnected...
05 Apr 2024
Understanding Project Scope and How to Specify Window Systems
It is vital that Movement and Deflection criteria are correctly defined in the Specification. We cannot over emphasize the importance of correctly...
04 Apr 2024
MBIE Building Consent System Review - Overview and Update
In July 2022, MBIE commenced a review of the building consent system, as part of the Building System Reforms to improve the consenting process. The...
30 Nov 2023
NZCIC Guidelines Responsibility Schedule Goes Digital
The new online tool enables real-time collaboration among multiple stakeholders, fostering efficiency and innovation in construction processes.
10 Nov 2023
BCA Requests to Modify Manufacturers Technical Content
mDocs allows the specifier to quickly access the latest version of a document uploaded by the manufacturer or supplier. Importantly, these detailed...
27 Sep 2023
Masterspec Specified: Award Winning Taharoto Lane by X Studio Architects
The development will have 19 units, including studio, office, and retail space. The residential units will have balconies with views of the city...
27 Sep 2023
Masterspec Specified: Award Winning Soaring Box House by Turner Road Architecture
The house’s unique design fits into the rural landscape. The house has a cantilevered structure and a soaring angular volume. The interior design is...
13 Sep 2023
Hallmark Group Opens Up About BPIR
Recently, Hallmark Group turned to Masterspec, a trusted name in compliance solutions, for guidance on their BPIR for fire doors. In this article, we...

BUILDING CODE AMENDMENTS 2018/2019

31 Jan 2019

In BC Update 243 MBIE announced that from the 30 November 2018 the transition period started for amendments to seven Acceptable Solutions and four Verification Methods. During the transition you can use either the old version or the new amended version. On the 31st March 2019 the amendments will become compulsory and the new amended versions must be used. However, after March if any previous versions were to be used, they must be considered an alternative solution proposal.

Summary of changes

The following is a brief description by MBIE of the changes to each amended Acceptable Solution or Verification Method, with a few additional comments from Masterspec.

B1 Structure: B1/VM1 (Amendment 17)

  • Paragraph 2.1: Added a reference to Amendments 4 and 5 of AS/NZS 1170.2:2011, Structural Design Actions - Wind Actions.

    Amendment 4 deals with debris loadings and internal pressures, Amendment 5 covers some table amendments. They do not affect Masterspec sections.

  • Paragraph 5.1.4A: Section 13 of NZS 3404.1:1997, Steel structures standard, which covers the design of component members and structures, has been replaced by AS/NZS 2327:2017, Composite Structures - Composite steel-concrete construction in buildings.

    This addition allows a wider range of composite structures to be designed under the NZBC.  Guidance notes on AS/NZS 2327 added to some Masterspec sections.

  • Paragraph 5.1.9A: B1/VM1, Appendix C: Corrosion Protection has been replaced with the new technical specification SNZ TS 3404:2018, Durability requirements for steel structures and components.

    Reference is given in B1/VM1 but is handled under B2/AS1 (see B2 notes below). This addition allows more designers to specify corrosion protection systems, refer to B2 comments.

  • Paragraph 12.1: Added a reference to Amendment 1 of NZS 4211:2008, Specification for performance of windows. 

    Amendment 1 adds Extra High wind zone, refer to E2 comments

Note; NZS 3404.1;2009 version has been withdrawn by Standards, which means NZS 3404.1;1997 version is the current version and is also cited by NZBC.

 

B2 Durability: B2/AS1 (Amendment 10)

  • Paragraph 3.6.1: The new technical specification SNZ TS 3404:2018, Durability requirements for steel structures and components has been added as an Acceptable Solution for structural steel building elements.

    This amendment provides clarity on acceptable methods of steel protection and avoids the need to justify alternative solution proposals. SNZ TS 3404 references and is based on the much more extensive AS/NZS 2312 set of Standards.

    Masterspec has added SNZ TS 3404 as a reference along with the existing references to the various parts of AS/NZS 2312. The AS/NZS 2312 set (referenced by SNZ TS 3404, but is not cited by NZBC.) has also been retained to keep a wider range of options, including proprietary ones, available for steel protection. Masterspec corrosive zone tables have been amended to include reference to SNZ TS 3404.

 

E2 External Moisture: E2/VM1, E2/AS1 (Amendment 8)

  • Paragraph 1.2: Added a reference to Amendment 1 of NZS 4211:2008, Specification for performance of windows.

    Amendment 1 adds Extra High wind zone category which brings it in line with NZS 3604. This new wind zone will require either Class 1 or Class 2 testing on new cladding systems for E2/VM1 compliance. The new testing requirements are for ensuring adequate weathertightness performance of claddings in Extra High wind zones.


    A rigid underlay is required in this situation, but is not part of the VM test of the cladding system. Note that the revised testing requirements will apply to all new testing, however current test certificates will remain valid. Masterspec sections were already using the Extra High wind zone, so they remain the same.

    Note; NZS 4211 has the same wind zones as NZS 3604 but uses different pressures for test purposes.

 

G12 Water Supplies: G12/VM1, G12/AS1, G12/AS2  (Amendment 11)

  • Cited Standards AS/NZS 3500.1:2015, Plumbing and drainage - Water services and AS/NZS 3500.4:2015, Plumbing and drainage - Heated water services, have both had an Amendment 1 added.

    Both of these Amendment 1's have added common Stainless Steel piping and jointing methods to the Standard, this effectively makes Stainless Steel piping an Acceptable Solution.

    Note; although this has not affected any of the Masterspec sections, while checking them we did take the opportunity to update and clarify, in the same sections, G12/AS1 requirements for overflow trays for storage HWCs.


G13 Foul Water: G13/AS1, G13/AS2, G13/AS3  (Amendment 7)

  • G13 cited Standard AS/NZS 3500.2:2015, Plumbing and drainage - Sanitary plumbing and drainage

    Has had Amendment 2 of the Standard added.


  • G13/AS1 Sanitary Plumbing, Paragraph 7.1.3 and G13/AS2 Drainage, Paragraph 6.1.3

    Have had a references added allowing air testing of pipework for water tightness to AS/NZS 3500.2, 15.3.

    This amendment provides another acceptable method of testing sanitary and drainage pipe work. Masterspec sections now include this option.

  • G13/AS3 Plumbing and Drainage, Paragraph 2.0.1:

    References added for Sections 15 (Testing) and 16 (Vacuum Systems) of AS/NZS 3500.2.

    As above, Section 15 amendment provides another acceptable method of testing drainage and this has been included in the Masterspec sections. Section 16 includes an acceptable solution for vacuum drainage installations. Vaccum drainage systems are very complex, the Masterspec sections do not cover such systems. However we have added a reminder guidance note recommending expert design advice if you need a vacuum drainage system.

 

Simple House: SH/AS1

  • MBIE had proposed to revoke SH/AS1 as part of the November 2018 Update.

    However they found that the ‘Slab-on-ground in expansive soils’ information for foundation design within SH/AS1 is not contained in any other Acceptable Solution. MBIE proposed to transfer this information to B1/AS1 in a future amendment. Once transferred, SH/AS1 will be revoked.