Masterspec
01 Apr 2025
Document Referencing and Scheduling with eCert
Our editor team has updated all Masterspec work sections which have references to environmental documents. Where environmental document references...
27 Mar 2025
Update Manager New Features
The new Update Manager features are designed to boost productivity when applying changes to updated work sections. Simplify work section updates with...
03 Mar 2025
CIL is Now Accepting Product Carbon Data for the National Embodied Carbon Data Repository for Construction.
CIL Masterspec is now accepting carbon information in the form of Environmental Product Declarations (EPDs) or Life Cycle Assessments (LCAs) from...
06 Jan 2025
Carbon 2025 and Beyond: Building a More Sustainable Future for NZ Construction
In July 2024, Construction Information Ltd (CIL) and the Building Research Association of New Zealand (BRANZ) announced a partnership to develop a...
01 Nov 2024
Introducing eCert: A Game-Changing Tool for Sustainable Construction
As the New Zealand construction industry increasingly focuses on sustainability and carbon reduction, there is a growing need for tools that can help...
26 Sep 2024
Masterspec Specified: Manawa House by Cube Architecture
"Masterspec has been an indispensable tool for our project Manawa House. During the specification, Masterspec streamlined our entire specification...
26 Sep 2024
Masterspec Specified: Award Winning Ligar Bay Bach by Young Architects
"Masterspec was used for providing a detailed, fully customised, specification as part of our comprehensive project documentation for the Ligar Bay...
25 Sep 2024
Masterspec Specified: Hilltop Home by Jon McAlpine Architecture
“Masterspec is a critical component in our studio. Its user-friendly platform and regular product specification updates, keep us constantly on the...
06 Aug 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
In Masterspec NOTES June 2024, we provided commentary around the changes to the NZ Building Code relating to domestic smoke alarms.
18 Jul 2024
New Industry Initiative to Reduce Carbon Emissions of New Zealand Buildings
A new industry-led initiative aims to reduce the environmental impact of Aotearoa New Zealand’s buildings, which contribute up to 20% of the national...
04 Jul 2024
Masterspec Announces New MasterKey4 for Revit 2025 Enhancements
Streamlined Workflows and Improved Collaboration with MasterKey4. We are excited to announce the latest update to MasterKey4 for Revit 2025, designed...
04 Jun 2024
Building Code Updates 2023-2024
This month we have published amendments in response to building code updates. The 2023-24 NZBC changes were published by MBIE on the 2 November 2023,...
04 Jun 2024
NZ Building Code Changes: Type 1 Domestic Smoke Alarms
From November 2023 the Building Code Acceptable Solutions for Protection from Fire (C/AS1 and C/AS2) have been amended to make Type 1 interconnected...
05 Apr 2024
Understanding Project Scope and How to Specify Window Systems
It is vital that Movement and Deflection criteria are correctly defined in the Specification. We cannot over emphasize the importance of correctly...
04 Apr 2024
MBIE Building Consent System Review - Overview and Update
In July 2022, MBIE commenced a review of the building consent system, as part of the Building System Reforms to improve the consenting process. The...
30 Nov 2023
NZCIC Guidelines Responsibility Schedule Goes Digital
The new online tool enables real-time collaboration among multiple stakeholders, fostering efficiency and innovation in construction processes.
10 Nov 2023
BCA Requests to Modify Manufacturers Technical Content
mDocs allows the specifier to quickly access the latest version of a document uploaded by the manufacturer or supplier. Importantly, these detailed...
27 Sep 2023
Masterspec Specified: Award Winning Taharoto Lane by X Studio Architects
The development will have 19 units, including studio, office, and retail space. The residential units will have balconies with views of the city...
27 Sep 2023
Masterspec Specified: Award Winning Soaring Box House by Turner Road Architecture
The house’s unique design fits into the rural landscape. The house has a cantilevered structure and a soaring angular volume. The interior design is...
13 Sep 2023
Hallmark Group Opens Up About BPIR
Recently, Hallmark Group turned to Masterspec, a trusted name in compliance solutions, for guidance on their BPIR for fire doors. In this article, we...

BUILDING CODE UPDATES 2019 - INTERIM REPORT

02 Aug 2019

Masterspec has almost completed its review of the updates to the approximately sixteen Acceptable Solutions and Verification Methods. Although one or two have made it into sections for this August release, we won't publish the majority of updates to Masterspec sections until our 1st September release. For those working on long term projects, we thought it might help if we give you few big-picture pointers on what to look out for.

On 27 June the transition period started for updates to the Acceptable Solutions and Verification Methods. They all become compulsory on the 1st November 2019, so from that date, if any previous versions of AS's or VM's are used they will be considered an alternative solution.

Summary of key updates

The following is a brief review of critical updates with a few additional comments from Masterspec:

B1 Structure: B1/VM1 (Amendment 18)

  • Paragraph 3.1.1: Hollow-core floor precast unit Maximum depth increase to 400mm.
  • Paragraph 5.3: Light steel framing (using NASH Standard Part 1) deleted and moved to NZBC B1/AS1.

B1 Structure: B1/AS1 (Amendment 18)

  • Paragraph 9.1: Light steel framing using new NASH Standard Part 2 added (was NZBC B1/VM1, 5.3).

 C Protection from Fire: C/AS2 (the new C/AS2 edition replaces the old C/AS2 to C/AS7)

This is a new document that replaces the six old documents C/AS2 to C/AS7. Note that C/AS1 remains unchanged.

Most of the text etc. remains the same, although they might have moved about (& renumbered). Some clause text has been put into new tables, and there are a few new Standards.

Major changes to Text:

  • Fire Safety Systems: New Table 2.2 (was Table 2.1) & A2.1.1. add a new system, Type 15 - Fire & Emergency New Zealand Lift Control.
  • Deleted clause 5.2.2, removing dispensation for cladding within 1m of the boundary if sprinklers are used.
  • New Table 5.5 (from old clause 5.8.1) for external cladding system requirements, standardises height to above or below 10m (deletes the old 7m option).

Major changes to Tables:

  • Old Table 4.1 for surface finishes (group numbers) has been split in 2 and renumbered. New Table 4.3 is Internal Surface Finishes, covers walls and ceilings. New Table 4.4 is Surfaces of Building Services (more detailed than the old table), covers the interior of ducts and exterior of pipes & ducts.
  • Old Table 4.2 Critical radiant flux for floors, is now Table 4.5 but virtually the same.
  • Old C/VM2 Table A1, about acceptable generic material Group Numbers, has been added to C/AS2 Table C1.2, with minor alterations such as adding tiling.

Major changes to Standards:

  • Old AS/NZS 1668.1 The use of ventilation and air conditioning in buildings - Fire and smoke control in multi-compartment buildings, has been replaced by AS1682.1 Fire Dampers - Specification, and AS1682.2 Fire Dampers - Installation, in clauses 4.16.12 & 4.16.14.
  • Ductwork Standard AS 4254 has been added to new Table 4.4 and fire test Standard AS/NZS 3837 has been added to new Table 5.5.


E2 External Moisture: E2/VM2 (new VM)

Introduces a new cladding system test using the BRANZ EM7 Test Specification, as a means of complying with NZBC E2.3.2. Note that this test allows cladding systems up to 25m in height, whereas apparently, NZBC E2/VM1 simpler tests are only up to 10m.

G4 Ventilation: G4/AS1 (new AS1 edition)

New Clause 1.2.5 makes it mandatory for household units and accommodation units to have mechanical extract fans for showers/baths (25 L/s) and cooktops (50 L/s). Passive Stack Vents have been effectively deleted from AS1.
Note; these changes have already been made to the relevant Masterspec sections, in particular, 7612 & 7612HE.

G12 Water Supplies: G12/VM1, G12/AS1, G12/AS2 (Amendment 12)

This mostly revolves around the adoption of new versions of AS/NZS 3500.1 & AS/NZS 3500.4.

  • AS/NZS 3500.1:2018, Plumbing and drainage - Water services, has replaced the old AS/NZS 3500.1:2015.
  • AS/NZS 3500.4:2018, Plumbing and drainage - Heated water services, plus Amendment 1, has replaced the old AS/NZS 3500.4:2015

G13 Foul Water: G13/AS1, G13/AS2, G13/AS3, G13/VM2 (Amendment 8)

This mostly revolves around the adoption of a new version of AS/NZS 3500.2.

  • AS/NZS 3500.2:2018, Plumbing and drainage - Sanitary plumbing and drainage has replaced the old AS/NZS 3500.2:2015.